WINDOWDRIVES ZUV2-24 V DC Secondary Locking Device ZWV Instruction Manual

June 3, 2024
WINDOWDRIVES

WINDOWDRIVES ZUV2-24 V DC Secondary Locking Device ZWV

WINDOWDRIVES-ZUV2-24 V-DC-Secondary-Locking-Device-ZWV-
PRODUCT

Electrically powered additional locking device for inward opening windows using a linear drive / sequential control combination

Technical dimensions

Area of application

The additional locking feature is a motorized locking device used on inward opening top-, bottom- and side-hung windows, serving as an additional lock in combination with linear drives on the same window.

Features

ZUV2-24 V DC

  • up to a maximum of 500 N shear / tensile
  • without integrated electronic power cut-off
  • automatic load-dependent switch-off when the end position is reached by utilizing an additional FS 3 – 24 sequential control
  • housing made from corrosion-resistant, drawn aluminum
  • possible parallel operations of multiple motors on one window through a parallel- or tandem control unit

ZWV

  • can be combined with a mechanical secondary locking device through a standard 1 m connector rod
  • non-standard length requirements for connector rod needs to be requested separately force

Safety instructions

Please observe the following safety which are emphasized by special symbols

  • Caution / Warning / Attention

  • Danger to persons due to electricity

  • Caution / Warning / Attention

  • Non-observance leads to destruction

  • Danger to material due to incorrect handling

  • Caution / Attention / Warning

  • Danger to persons due to risks arising from the operation of the equipment. The danger of crushing/trapping

  • INFO

  • Warning 230 V AC

  • Dangerous voltage. Can cause death, serious injury or considerable material damage. Disconnect the equipment from the power supply at all poles before opening, assembling or carrying out any structural alterations. Observe VDE 0100 for
    230 V power connection.

  • Please observe the following for assembly and operation

  • The window closes automatically.

  • When opening and closing, the drive unit is stopped by the power cut-off. The corresponding pressure force is listed in the technical data. Take care – the pressure force is high enough to crush your fingers.

  • During assembly and operation, do not interfere with the window gap or the travelling drive!

  • Danger of crushing/trapping!

  • Operating instructions

  • for professional assembly, installation and appropriate maintenance by trained, qualified and safety-conscious electricians and/or skilled staff with knowledge of electrical equipment installation.

  • Read and observe the information contained in these operating instructions and respect the order of procedure stated therein.

  • Please keep these operating instructions for future reference and maintenance. Reliable operation and the prevention of damage and risks are only granted if the equipment is assembled carefully and the settings are carried out according to these instructions and to the operating instructions of the drives.

  • Please observe the exact terminal assignment, the minimum and maximum power ratings (see technical data) and the installation instructions.

  • Application range

  • Exclusively for the automatic opening and closing of the stated types of windows. For further application, please contact the manufacturer.

  • It would be beyond the scope of these safety instructions to list all the valide regulations and guidelines.

  • Always make sure that your system corresponds to the valid regulations. Pay particular attention to: the aperture cross-section of the window, the opening time and opening speed, the temperature resistance of the cables and equipment, cross-sections of the cables in relation to the cable lengths and power consumption. Required mounting material is to be adapted to the frame and the corresponding load and is to be completed, if necessary. Any supplied mounting material is only part of the required amount.

  • Maintenance works

  • If the equipment is employed in smoke heat extraction systems (in short SHE), they must be checked, serviced and, if required, repaired at least once per year. This is also recommended for pure ventilation systems.

  • Free the equipment from any contamination. Check the tightness of fixing and clamping screws. Test the equipment by trial run.

  • The gear system is maintenance free. Defective equipment must only be repaired in our factory. Only original spare parts are to be used.

  • The readiness for operation has to be checked regularly. For this purpose a service contract is recommended. All batteries provided with the SHE control centre need to be regularly checked as part of the maintenance programme and have to be replaced after their specified service life (approx. 4 years). Please observe the legal requirements when disposing of hazardous material – e.g. batteries.

  • Routing of cables and electrical connections only to be done by a qualified electrician. Power supply leads 230 V AC to be fused separately by the customer. Keep power supply leads sheathed until the mains terminal.

  • DIN and VDE regulations to be observed for the installation: VDE 0100 Setting up of high voltage installations up to 1000 V. VDE 0815 Installation cables and wires. VDE 0833 Alarm systems for fire, break-in and burglary.

  • Cable types to be agreed with local inspection authorities, power utilities, fire protection authority and the professional associations. All low voltage cables (24 V DC) to be installed separately from high voltage cables. Flexible cables must not be plastered in. Provide tension relief for freely suspended cables. The cables must be installed in such a way that they cannot be sheared off, twisted or bent off during operation. Junction boxes must be accessible for maintenance work. Adhere to the type of cables, cable lengths and cross-sections as stated in the technical information.

  • The supply voltage and the batteries are to be disconnected at all poles before maintenance work or structural alterations. The system must be protected against unintentional re-starting. Electrical controls must be voltage free before extension modules are taken off or added (disconnect mains voltage and batteries).

  • After installation and any changes to the system check all functions by a trial run.

  • During assembly and operation, please observe: the windows may close automatically.

  • Potential crushing and cutting points between the casement and the window frame, dome lights and support frame must be secured up to a height of 2.5 m by safety equipment, which if touched or interrupted by a person will immediately stop the movement
    (guideline for power operated windows, doors and gates of the professional association).

  • For applications: Tilt windows: A scissor-type safety catch is to be installed. It prevents damage caused by incorrect assembly and handling. Please observe: the scissor-type safety catch must be adapted to the opening stroke of the drive unit, i.e. that the opening of the safety catch must be larger than the drive unit stroke in order to prevent blocking. See guideline for power-operated windows, doors and gates. Provide all aggregates with durable protection against water and dirt!

  • Attention: The control must only be operated with drives made by the same manufacturer. No liability will be accepted and no guarantee nor service is granted if products of outside manufacturers are used. Assembly and installation must be carried out properly, according to the information of the operating instructions paying particular attention to safety aspects. If spare parts, dismantled parts or extension components are required or desired, only use original spare parts.

  • Manufacturer’s declaration

  • The equipment has been manufactured and tested according to the European regulations. A corresponding manufacturer’s declaration has been submitted. You may only operate the system if a Declaration of Conformity exists for the entire system.

Fields of application

  • Side-hung window equipped with one linear drive and ZUV2-24 V DCWINDOWDRIVES-ZUV2-24 V-DC-Secondary-Locking-Device-ZWV-FIG-2
  • Bottom-hung window operated by two linear drives in parallel operation and ZUV2-24 V DCWINDOWDRIVES-ZUV2-24 V-DC-Secondary-Locking-Device-ZWV-FIG-3

Assembly

  1. Mount actuators in retracted position. Make sure that actuator and bracket are safely attached. Secure eyebolt after adjustment. Take possible pivoting range of actuator into consideration. Window needs to be tightly fastened in “CLOSED” position. Do not operate motors without tandem power
    cut-off or parallel power cut-off switch and without synchronization control.

  2. Inward opening windows: need to be secured against falling by a window manufacturer provided safty catch.

  3. Do not exceed the power line length to the next distributor box. Note: Cable diameter requirements – length vs. Current flow!Monitoring of power supply cable takes place to the last distributor box, or to the last tandem-, parallel power switch-off control, respectively

  4. Pay close attention to the enclosed wiring diagram when connecting the motors.
    Use the appropriate instructions for the particular motors, tandem power cutt- off or parallel power cut-off controls and the control panels in use.

  5. After thoroughly checking all connections and lines:
    tigger “OPEN” signal on control panel. Actuators should move in “OPEN” running direction. Correct incorrect running direction of individual motors by reversing polarity of power lines.

  6. After several trial runs: double check secure positioning of motors and attachment screws.

10 mm aluminium mounting plate, colour Ev1 anodizedWINDOWDRIVES-ZUV2-24 V
-DC-Secondary-Locking-Device-ZWV-FIG-4

Electrical connection

Laying of cables and electrical connection should only be carried out by an approved electrical company.
The power cables must not be strained by tension, twisting, squashing or by shearing off. Follow the valid regulations (see page 2).
Attention
Do not operate without external power cut-off, for example the sequential control FS 3-24 V DC, parallel- or tandem power cut-off control.
Unit may self-destruct! Connection and mounting see appropriate users manual.

Junction box customers resposibility

Technical data SUV 2

  • Input and operating voltage: 24 V DC (+20% / -8%)
  • Max. Power consumption: approx. 0.65 A
  • Pressing / tractive force: 500 N
  • Stroke lengths: aligned with bolt lock device
  • Cut-off: electronic load-dependent switch-off with FS 3-24 V DC sequential control
  • Power cable: 2 x 0.5 mm² length approx. 2.5 m silicon white
  • Start-up time: S3 / 30% gem. VdS 2580
  • Operating time: approx. 5 sec.
  • Range of temperature: -5° C to +65° CIP 54 according to DIN 40050X
  • Protective system: / EN 60529
  • housing material: special aluminum profile, 35 x 35 mm
  • Length: 303 mm / motorized locking device
  • Colour (standard): EV1/silver anodized
  • Special color: on request to RAL-colour card35 mm mounting plate for
  • Accessories: casement overlap 5-35 mm, order extra
  • The illustration of the installation on site is only a scheme and not binding. It does not replace the required detailed plans. Valid from printing date until the next edition.