zyrosite V31 150km Video Data Link User Manual
- July 30, 2024
- zyrosite
Table of Contents
- zyrosite V31 150km Video Data Link User Manual
- 1. Disclaimer
- 2. Product Precautions
- 3. Product Introduction and Parameters
- 4. Item list
- 5. Interface instruction
- 6. Product Instruction
- 7. LAN Port Operation
- 8. USB Port Operation
- 9. Network Function
- 10. Module Configuration
- 11. Remote Control Fail-Safe Protection Setting
- 12. Firmware Version View
- 13. Firmware Upgrading
- 14 Common Questions
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
zyrosite V31 150km Video Data Link User Manual
V31
1. Disclaimer
Thank you for purchasing the V31 video&data&RC link. Please use it following the local radio control regulations and read this statement carefully before using it. Once used, it shall be deemed to endorse and accept all contents of this statement. Please strictly follow this instruction to install and use the product. The supplier will not bear any legal liability for any result or loss caused by improper use, installation, final assembly or modification of the product.
2. Product Precautions
- V31 airborne unit and ground unit need external power supply input DC7.4-30V (lithium battery 2s-6s), please follow the specification to power the radio.
- Be sure to install the antenna before powering up to avoid damaging the circuit.
- Ensure that the antennas are free from obstruction and bending, and keep them as far away from large metal objects as possible to avoid blocking communication for the above reasons.
- Please do not disassemble or modify the V31. If you encounter any problems that cannot be solved during installation or use, please contact Chinowing Technology Co., Ltd.
- Make installation with proper distance between electronic devices to minimize electromagnetic interference.
- Before use, make sure that all wiring is securely fastened and that all components are working properly.
- Please check the surrounding environment to ensure that there is no interference from other devices in the same frequency band before use, otherwise, the data transmission of V31 may be seriously affected
- If you encounter any problem during the installation or use, please contact us or visit our website at www.chinowing.com for technical support.
3. Product Introduction and Parameters
V31 Digital video and data transmission module is the wireless digital data
link based on LTE wireless communication, adopting OFDM and MIMO technology.
It can transmit telemetry data and real-time video streaming and has 2*SBUS
ports, able to provide control of the drone and the payload.
There are 2 frequencies for choice, 800MHz and 1.4GHz.
High integration greatly reduces the power consumption and the dimension of
the product, which can satisfy the requirement of UAV, UGV, etc.
4. Item list
5. Interface instruction
Front view
- Data receiving indicator: light will flicker in the condition of data receiving.
- Data transmitting indicator: light will flicker in the condition of data transmitting.
- Signal strength indicator: green light indicates signal strength; red light indicates abnormal antenna bottom noise.
- SET button: used for firmware upgrading, serial port baud rate setting, out-of-control protection settings
- SMA antenna connector: main antenna, able to transmit and receive signal.
- SMA antenna connector: secondary antenna, able to receive signal.
Side view
-
TTL port: full duplex serial port(RS232 optional)
-
S-BUS1port: SBUS input(ground unit);SBUS output(airborne unit)
-
S-BUS2 port: SBUS input(ground unit);SBUS output(airborne unit)
-
Power supply port: 7.4-30V
-
TTL/RS232 signal indicator: light will flicker when there is data input.
Indicator flashes in light blue, it is TTL signal.
Indicator flashes in green, it is RS232 signal. -
SBUS1 indicator:
Ground unit: SBUS1 indicator will flicker when there is data input of SBUS1.
Airborne unit: SBUS1 indicator will flicker when there is data output of SBUS1. -
SBUS2 indicator:
Ground unit: SBUS2 indicator will flicker when there is data input of SBUS2.
Airborne unit: SBUS2 indicator will flicker when there is data output of SBUS
LAN port: for video input or output
USB port: debugging interface. After the driver is installed, a virtual NIC
can be used
6. Product Instruction
Power on the airborne unit and ground unit. After the successful connection of the two modules(signal indicator is constant, this process takes about the 30s), the device can work normally, and all parameters have been configured well. If you want to modify the baud rate of the serial port and the IP address of the network port, please refer to the corresponding steps.
Note! The products are factory configured and ready for use. Default
configuration parameters.
User name: admin123
Password: admin123
LAN port IP: 192.168.168.12 (airborne unit); 192.168.168. 11(ground unit)
Secret key: 88
Wireless parameters: frequency: 1.4G/800MHz; frequency hopping mode: enabled;
bandwidth: 20M
Serial port parameters: baud rate: 115200; 8 data bits; 1 stop bit; no parity
6.1 S-BUS port operation
- Connect the SBUS port of V31 ground unit with the SBUS signal source of RC receiver. The SBUS indicator will flash quickly when there is data input.
- Connect the SBUS port of V31 airborne unit to the device you need to control.
- V31 can control aircraft, gimbal and other devices as long as the link is connected.
6.2 Indicator light instruction
6.3 Abnormal bottom noise
When S1 red light is flashing, the main antenna has poor bottom noise; when S2
red light is flashing, the secondary antenna has poor bottom noise.
Please check whether there is any abnormality of the corresponding antenna, feeder line, connection and installation position when there is bottom noise fault phenomenon, otherwise it will affect the transmission distance.
The bottom noise prompt function is suitable for the pre-flight check, like indoor installation and debugging. It works in the range of 200 meters between Tx and Rx after V31 link successful connection. This function will be closed automatically after the range is more than 200 meters.
For the bottom noise test, pls try to avoid going through walls, etc, in case of inaccurate results. Pls, do it in the LOS condition.
6.4 Check the frequency
V31 has 2 frequencies for choice, 800MHz, 1.4GHz.
For frequency checking, pls press the SET button <3 seconds when power on, S3 indicator light Red indicates 800MHz; S2, S3 indicator lights Red indicates 1.4GHz.
6.5 Serial port use
The default baud rate of the serial port is 115200. Pls, follow the below
methods to connect the flight control and ground station software.
- Connect flight control to the airborne unit. Pls kindly be noted the line sequence as well as the baud rate of the flight control port must be the same as the baud rate of the serial port.
- Connect the ground station software to the ground unit. Pls kindly be noted that the line sequence as well as the baud rate of the port selected by the ground station software must be the same as the baud rate of the serial port.
6.6 Serial port baud rate change
Press and hold the SET key after the module is powered on(about 3 seconds).
When RX and TX light up, release the key, which indicates that the module has
entered the mode of changing the baud rate. After entering the mode, press the
SET key briefly (<1 second) to switch the baud rate. The corresponding LED ON
represents the corresponding baud rate value.
Details are as follows:
After finishing the setting, long press the SET key (about 2 seconds). When TX and RX light up at the same time, pls release the key. After release, the indicator will return to the normal working state. After the modification is completed, the baud rate needs to be re-powered to take effect.
Note: when changing the baud rate, it needs to be the same for the airborne unit, ground unit, flight control, or other devices for normal communication.
7. LAN Port Operation
Pull-streaming video can be acquired using the LAN port
-
Default IP address:
airborne unit: 192.168.168.12; ground unit: 192.168.168.11 -
Connect the LAN port of the airborne unit to IPC devices.
-
Connect your computer to the LAN port of the ground unit, and make sure that the IP address of your computer’s local connection is on the same network segment as the camera.
①Open Computer network sharing center
②Open the Change Adapter option
③ Select the local connection to the ground unit and right-click on it to view the properties.
④Select Internet IPV4 protocol, set the fixed IP, and set the IP to the same network segment as the camera, e.g.: the camera IP is 192.168.167.10, set the local IP to 192.168.167.xxx (0~255) except 10. When the modification is finished, click “OK”.
⑤ Capture and play the video data using streaming software such as VLC Media Player.
- Pls, ignore the IP address of V31 when setting the IP address in getting video by pull stream. Just change the local IP address of the computer to the same network segment as the LAN camera.
- For more tutorials, please refer to our website www.chinowing.com.
8. USB Port Operation
The USB port incorporates a virtual network card function that can be used for video and data output. Before using the USB port, the user must install the appropriate driver. The steps are as follows:
- Install V31 CODEDRIVER driver
- The installation process may be intercepted by the security guard, please close the security guard or trust this operation. After the successful installation, connect the USB port to the PC, and open Computer->Management, you can see 5 ports will appear in the port management interface(not open for use yet). < Remote NDIS-based Internet Sharing Device> will appear in the interface of the network adapter, indicating that the USB port connection is successful.
Note: Please do not use the USB port until the device is successfully connected. Otherwise, the signal strength indicator may appear abnormal.
3. Open the Network Sharing Center and set the local connection to get static IP.
9. Network Function
V31 Radio supports network communications and is a point-to-multipoint product that supports up to 16 slave devices. The ground unit can be set as the master and the airborne unit as the slave. The ground unit can be connected to max 16 airborne units, and through the TTL interface, the ground unit can transmit data to 16 airborne units. The data transmitting and receiving can be realized through LAN port between airborne units. Operation steps are as follow:
1. Set the ground unit as the master device.
2. Set the airborne unit as the slave device
3. The IP address of the ground unit and other airborne units must be in the
same network segment, and cannot have the same IP address to avoid IP
conflicts and inaccessibility. For
example, the ground unit IP is 192.168.168.11, other airborne unit IP is
192.168.168.12, 192.168.168.13…
4. Data is input from the TTL interface of the ground unit and data can be
received by the TTL interface of each airborne unit.
5. The airborne unit accesses other IP-connected devices of the other
airborne unit(e.g., LAN camera, etc.) via a network interface IP.
a. The IP address of the camera connected to the airborne unit is
192.168.167.20;
b. Other airborne units connect to PC via Ethernet port, set local connection
to static IP, IP is on same network segment as camera, eg.192.168.167.30;
c. Use pull stream software to play the video.
10. Module Configuration
Take <airborne unit LAN port IP: 192.168.168.12; Ground unit LAN port IP:
192.168.168.11 > for example:
- Power on the modules. Wait for the module to start for about 30s, connect the PC to the LAN port of the ground unit through the network cable to access the airborne unit directly from the ground unit, or connect the airborne unit to the computer separately.
- Set the local IP to static IP in the computer network sharing center, IP should be the in the same network segment with airborne unit IP, for example.192.168.168.15.
③Open a browser and enter IP in the address bar: 192.168.168.11
④Pop up the login interface and click on the administrator login, user name:
admin123, password: admin123.
If the login doesn’t work or writes “This browser does not support
ActiveObject, download another browser (e.g. Sogou or Microsoft Edge) or
update your browser version and try again.
⑤After successful login, the module configuration interface will appear.
< Key Settings Management> allows the user to set the secret key, whichmust be the same between the airborne unit and the ground unit for communication.-
It is recommended that you do not modify the
of the to avoid the possibility of poor communication quality due to improper settings. -
can modify the frequency band, bandwidth, power and frequency hopping. When modifying the frequency band and bandwidth, please make sure the frequency band and bandwidth of the airborne unit and ground unit should be the same, the antenna model used is consistent with the frequency band. In different sub-model, the max power is different. -
can modify IP addresses. It is not recommended to change the IP address randomly. If the user wants to change it, please make sure that the ground unit and the airborne terminal are on the same network segment. -
allows the user to change the ratio of uplink rate to downlink rate. If there is not any question, it is not recommended to modify it. If it is needed, the airborne unit setting is valid, - <1D4U> means the ratio of downlink and uplink is 1:4.(master node to slave node is DOWN, slave node to slave node is UP).
To ensure smooth video play, there are different parameters settings in
different application scenarios:
Scenario 1:
Scenario 2:
Scenario 3:
The
- The first parameter is the frequency point range, please set it according to the frequency point range of different frequency bands.
- The second parameter is the bandwidth, 1 is 3M; 2 is 5M; 3 is 10M; 5 is 20M;
- The third parameter is the power, which ranges from <40db ~ 25dbm>.
As shown below: 4D1U
⑥
11. Remote Control Fail-Safe Protection Setting
If the RC fail-safe protection is needed to be set, pls follow the below steps:
11.1 Write fail-safe protection data
After the successful connection of the airborne unit and ground unit, press and hold the SET button about 5S when there is SBUS data transmission.
When RX, TX, S1, S2, S3 all lights ON, it means entering Failsafe data setting mode, and then release the SET button.
Press the SET button briefly to switch to write failsafe data or turn off fail-safe, when RX and TX flash, it means the setting is successful.
Press and hold the SET button until RX, TX, S1, S2, S3 all lights are ON, which means Failsafe data has been saved and exit setting mode.
After finishing the setting, the current RC value can be stored in the
airborne unit as a failsafe value, and will not be lost after power failure.
S1, S2 and S3 will flash when failsafe
data is output. Please test whether the Failsafe data is written successfully
by the flight control, GCS or servo.
11.2 Trigger Fail Safe Value
If the airborne unit does not receive SBUS data from the ground unit for 3
seconds, the airborne unit will keep outputting the Fail safe value written
before, and the S1, S2, and S3 signal lights will flash until it receives SBUS
data from the ground.
11.3 Turn off Fail-Safe Value
Long press the SET key (about 5S) after powering on the airborne unit. When
all lights are ON, it means the Failsafe data setting mode has been entered,
then release the SET key. Press the SET button briefly to switch to <write
fail-safe data> or
11.4 Reset fail-safe data
If the user needs to reset the SBUS fail-safe data,
it enters fail-safe setting mode when there is RC SBUS data transmission.
First, short press the SET button to cancel the fail-safe data set previously,
then short press the SET button briefly. When the RX and TX lights flash, it
means successful setting.
- By default, there is no fail-safe data output from the radio, it will continue to output the last received SBUS data after the data link is disconnected.
- Only the S-BUS channel that has input at that time will be triggered and deactivated fail-safe function. For example, if the S-BUS1 channel has data transmission and the S-BUS2 channel has no data transmission, pressing the key will only trigger and deactivate S-BUS1 fail-safe data.
- To set up fail-safe for both S-BUS1 and S-BUS2 at the same time, both S-BUS1 and S-BUS2 are required to have remote SBUS data transmission.
12. Firmware Version View
To serve our customers better, our R&D team never stops the work. We are upgrading the firmware and software, so please check the firmware version when you use it and refer to our website for the latest version of the software and firmware.
The version of the parameters setting software can be seen directly on the PC when you configure the parameters, and the firmware version can be viewed through the following steps
- Connect the radio to the PC via a USB cable, and a COM port will appear on the PC side.
- Install the serial port debugging assistant on your PC and open this port. Port configuration parameters: 115200, 8N1. string display mode
- After powering on V31, the serial assistant will show the following firmware version information <V31SX-1.0—-V31SX-0.0.2—-sysbaud:115200>.
- V31RX indicates the airborne unit, the first version number indicates the hardware version number of the firmware, and the second version number indicates the software version number of the firmware. As the above version number represents the V31 airborne unit, the hardware version number is 1.0, and the software version number is 0.0.2.
13. Firmware Upgrading
Please use the firmware upgrade tool to upgrade the firmware separately for the ground unit and airborne unit.
- Connect V31 to the computer with the matched configuration cable TTL-to-USB cable. (White – TX, Black – G, Green – RX)
- Long press the set key to power on, then release the key when the RX and TX indicators are continuously ON. Open the upgrade software within 1 minute. The corresponding message will pop up, which means it enters upgrade mode.
14 Common Questions
-
Show weak signal strength
Check whether the antennas are connected well, and whether there are other high-powered devices nearby, and adjust the distance between the devices and the orientation of the antennas. -
Unable to stream video in the video player
Please make sure that the IP address of the receiver is in the same network segment as the IP camera. -
Receiver SBUS has signal output, but the serial port is not connected, or the transmitted signal is garbled.
Please check if the baud rate of the serial port of the remote control and the receiver is the same; and set the baud rate to the corresponding baud rate of the ground station software. -
Interference when more than two sets of device are turned on at the same time
Please check that the ID (key) must be different from each set, and set it differently to avoid co-frequency interference. -
Significant packet loss and high latency of video transmission
a. Check and confirm the antennas are connected well
b. Check and confirm module versions are consistent
c. Check whether the module wireless setup parameter is consistent.
d. Check that other devices, device cables, and computer interfaces are working properly.
e. Check the settings of image streaming software or change other player
Read More About This Manual & Download PDF: