Saflok Quantum Adese Odyssey RFID Instruction Manual

July 26, 2024
Saflok

Quantum™ ädesē ® (Odyssey) RFID

Installation Instructions

All parts needed to install the Quantum™ ädesē ® RFID lock are included with each unit. Please check to make sure all parts are accounted for before beginning installation. Do not substitute any of the parts. The use of substitute parts will result in poor performance of the lock.

  1. Screw Pack (A29050-COLOR)

  2. Proximity Reader Assembly (A20910-COLOR)

  3. Gear Box For the standard mortise only (24012-1)

  4. Inside Trim Assembly (QP12XXX-6-XX)

  5. Strike Plate (30320-HAND-COLOR)

  6. Scalp Plate (51190-COLOR)

  7. Mortise Lock (A59810-HAND-G)
    Mortise, Std.
    OR
    (A59850-HAND-G) Mortise, ADB
    OR
    (A60000-HAND-G) Mortise, MT, STD, DAJ
    OR
    (A59990-HAND-G) Mortise, MT, ADB, DAJ)

  8. Outside Lever Trim (A20970-HAND-COLOR)

All information contained herein, including but not limited to product pricing and other intellectual property, is confidential and intended for the sole use of the addressee(s) so named. Any misuse of this confidential information contained herein may result in legal action by Computerized Security Systems dba SAFLOK and its parent company.

Preparing the door and door frame

1. Prepare the door using the Quantum RFID reader installation template or drill fixture. The door edge prep is a standard, full-mortise prep for a 1-1/4″ x 8″ front plate (1″ x 8″ and 1″ x 7-3/4″ custom front plates are optional). The door surface holes and mortise are customized for the SAFLOK trim.

Important: Some holes are only on the inside surface of the door.

  • For new construction installations, the door manufacturer may prepare the door using the installation template.
  • For retrofit installations, remove the existing hardware and confirm that the existing door edge prep is appropriate for the SAFLOK mortise lock.

Drill fixture: If you are using a SAFLOK drill fixture, position and clamp the fixture on the door. The fixture has two positioning posts that rest inside the mortise, establishing the proper backset for the trim. When the fixture is clamped, its surfaces should be parallel with the door surfaces and door edges. Not all holes go through the door (refer to the template). Notch the material on the inside surface for easier routing of the motor wire. After machining, remove any debris from the mortise and cutouts.

2. Prepare the door frame using the template and install the strike plate using the screws provided (12 x 1-1/2 screws for wood frames, 12-24 x 3/8 screws for metal frames).

3. The mortise plate has an adjustable bevel. Align the mortise front plate with the bevel of the door edge and tighten the two bevel adjustment screws at the top and bottom of the mortise case. Position the mortise case in the door edge with the motor wire routed through the notch (see Fig. 1).

Note: Use care to ensure that the wires do not get pinched or pulled as the mortise is inserted into the pocket.

Fig. 1

A: Inside Door Surface

  1. Mortise Front Plate
  2. Mortise Screws
  3. Motor Wire
  4. Notch for routing the motor wire (inside only)

4. Attach the mortise front plate to the door using the two mortise screws (12 x 1-1/4 screws for wood doors, 12-24 x 3/8 screws for metal doors). Be sure that the screws are fully tightened.

Important: DO NOT leave the screws loose. The screws must be fully tightened before the trim is installed. If you must leave the mortise loose to install the trim, the door preparation is incorrect.

5. Install the scalp plate with the 8-32 x 1/4 screws provided and test for proper mechanical latch engagement into the strike plate.

Installing the lock trim

The outside lever trim has two carriage bolts that fit into the diagonal holes in the mortise case. These carriage bolts establish an accurate trim position with respect to the mortise case assembly, allowing the levers and bolt mechanism to operate without binding. The holes machined in the door surfaces should not influence the position of the trim or the proximity reader assembly.

Do not tap or bend the carriage bolts to manipulate the fit of either trim piece during installation. The door prep holes should accommodate the outside lever trim and the proximity reader assembly. If the carriage bolts or proximity reader enclosure fit too tightly in the door prep holes, then remove the mortise and enlarge the holes to achieve a free fit.

1. Remove the battery pack and retaining spring.
2. Position the outside proximity reader assembly on the outside of the door (see Fig. 2). Route the ribbon cable and power cable through the 13/16” hole in the door.
Do not pull on the ribbon cable.

Fig. 2

  1. Proximity Reader Assembly
  2. Power Cable
  3. Ribbon Cable
  4. Outside Lever Trim
  5. Motor Wire
  6. Inside Trim
  7. 8-32 x 1-1/4 Screws
  8. M5 x 0.8g x 31 mm Screws

3. Route the ribbon cable and power cable through the rectangular hole in the inside trim. Do not pull on the ribbon cable. This hole is located above printed circuit board (PCB) assembly. Route the motor wire through the wire channel in the inside trim closest to the door edge. These holes are located below the PCB (see Fig. 3).
4. Position the inside trim on the inside of the door.
5. Secure inside trim to the proximity reader assembly using two M5 x 31 mm screws.
Important: Do not fully tighten the screws at this point.
6. Align the outside lever trim with the diagonal holes located on either side of the mortise hub and secure it by starting the two 8-32 x 1-1/4 screws (see Fig. 2).
7. Once the outside lever trim is fully secured, check the alignment of the inside trim and be sure that the both levers rotate without binding. Once the trim is properly aligned, fully tighten the four screws that secure the trim to the door and check for proper rotation.
8. Place the battery pack in position above the PCB and secure it in place using the retaining spring. Be sure that the battery wire is routed through the lower left corner of the battery compartment.
9. Connect ribbon cable and motor cable to the PCB.

Fig. 3

  1. Route the ribbon connector through the rectangular hole
  2. Motor Wire Channels

10. Watching for the green LED on the proximity reader to flash four times, connect the battery wire to the PCB. The green light indicates that the PCB has reset.
Important: The battery wire should be the last connection made to the PCB.
11. With the dead bolt retracted, insert the long end of the dead bolt spindle assembly through the PCB switch cam hole and into the mortise dead bolt hub. The indicator marks on the switch cam should be at the right (3:00 position) when the mortise dead bolt is retracted (see Fig. 4 on the following page). The retaining ring should rest on the switch cam when fully inserted (the proper positioning of the cam will allow the door to be opened when the dead bolt is retracted and block entry when the dead bolt is thrown for privacy, except when emergency keycards are used). Position dead bolt spindle assembly into cam assembly.
Important: As illustrated in Fig. 4, be sure that the cam is in correct orientation.
12. Install the inside escutcheon with the thumb turn pointed upward.
13. Secure the inside trim cover to the inside trim using two color-matching M4 x 16mm Torx screws (see Fig. 5 on the following page).
14. Program the lock using the Quantum RFID LPI Probe. Test the functioning of the lock as discussed in the following section and the programming manual before closing the door. When the construction key is used, the red and green LEDs will blink together, indicating that the time and date are not set.

Fig. 4

A: Route ribbon upward over battery

  1. Battery Wire
  2. Green Ground Wire
  3. Battery
  4. Ribbon
  5. Dead Bolt Spindle Assembly
  6. Motor Wire
  7. Motor Connection
  8. Battery Connection (last)
  9. Ribbon Connection
  10. 3:00 Position ADB Mortise

Fig. 5

  1. M4 X 16mm Torx Screws
Testing Lock Functionality

Pass a Construction key over the Quantum RFID LPI probe. Be sure that the green light flashes for five seconds while the exterior lever remains operable. If the green light does not flash, refer to the table below.

Lock Communication Electronic Function Description
Red and green LEDs flash nine times simultaneously Time and date not

set, use the Quantum RFID LPI probe to reset
Yellow LED flashes 12 times| Dead bolt is thrown or switch cam is not properly aligned
Yellow LED flashes two times| Keycard not allowed OR keycard canceled by new keycard
Red and green LEDs flash alternately nine times| Low battery (contact the SAFLOK service department)
Yellow and red LEDs flash two times simultaneously| Bad keycard read or corrupted data (may require new keycard)
Red LED flashes two times| Keycard not read (keycard inserted upside- down, wrong end, wrong key?)

FCC and ISED Information

ISED non-interference disclaimer This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This equipment complies with ISED RSS-102 radiation exposure limits set forth far an uncontrolled environment. This transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

RF Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. To avoid the possibility of exceeding the FCC radio frequency exposure limits, this equipment should be installed and operated with minimum distance 20 cm between the antenna and your body during normal operation. Users must follow the specific operating instructions for satisfying RF exposure compliance.

Quantum RFID Electromechanical lock series

Product’s Description Product ID FCC/ISED Information
Quantum RFID: Electromechanical lock with RFID and BLE QRFID6  Model No: MT6

Quantum RFID
FCC ID: SAPQUANTUMRF6
IC: 4652A-QUANTUMRF6
Quantum RFID Adese: Electromechanical lock with RFID and BLE with ADESE internal escutcheon| QRFID6-AD| Model No: MT6 Quantum RFID
FCC ID: SAPQUANTUMRF6
IC: 4652A-QUANTUMRF6
Quantum RFID with Messenger: Electromechanical lock with RFID and BLE with Messenger module.| QRFID6-M| Model No: MT6 Quantum RFID
FCC ID: SAPQUANTUMRF6
IC: 4652A-QUANTUMRF6
Contains:
FCC ID: Q8S515123
IC: 4652A-515123
Quantum RFID Adese with Messenger: Electromechanical lock with RFID and BLE with ADESE internal escutcheon and Messenger module.| QRFID6-ADM| Model No: MT6 Quantum RFID
FCC ID: SAPQUANTUMRF6
IC: 4652A-QUANTUMRF6
Contains:
FCC ID: Q8S515123
IC: 4652A-515123

SAFLOK Door Unit Inspection Criteria

Appearance

  • Finish is free of blemishes or scratches that would distract from lock appearance
  • Lock body and under plate (if used) are mounted straight on the door
  • Door scalp is mounted straight and flush with the door edge
  • Jamb strike is mounted straight and is flush with the jamb face
  • Correction of minor blemishes on the door jamb are the responsibility of the property’s maintenance department

Lock Function

  • Knob or lever rotates and moves freely
  • Lever is horizontal to floor when at rest position
  • Dead bolt extends fully and retracts without binding (door open)
  • Lock latch and dead bolt engage jamb strike plate freely
  • Anti-pick latch when depressed (door open)
  • Anti-pick latch is depressed when contact is made with the strike plate (door closed)

Electronics/Keycards

  • Keycard can be inserted and withdrawn freely
  • Yellow light flashes twice when incorrect keycard is used
  • Red light flashes twice if keycard is used incorrectly and cannot be read (e.g., a credit card is used)
  • Green light flashes when the proper keycard is used
  • Green light is flashing when the lever is operated
  • Green light continues to flash for a five-second cycle
  • Yellow light flashes 12 times when the dead bolt is extended and a guest/hotel keycard is used
  • All keycards function to the specifications of the master plan

Door function

  • Door closes and latches with little or no interference
  • Dead bolt extends fully through the strike plate without interference (door closed)
  • Spacing between door edge and inside door jamb does not exceed 3/16″ (door closed)

Note: If bumpers or other seals are added after strike plate installation and causes alignment and latch problems, it is the property’s responsibility to correct this condition. This note generally applies to new construction or new door installation.

FCC Warning: The users of this equipment shall not change or modify the equipment in any way, or they could void their authority to operate the equipment under FCC rules.

Questions? Call Customer Service at 800.999.6213 and select option 3.
For online assistance, visit support.saflok.com.

For worldwide office locations and contact information, visit us at
www.saflok.com.

USA • Canada
Phone: 877.272.3565

Europe • Middle East • Africa
Phone: 33.1.30.13.04.04
Asia
Phone: 86.10.5861.3561

Manufactured under one or more of the following patents:
U.S.: 4,177,657; 4,411,144; 4,534,194; 4,890,870; 5,198,643; 5,477,041; 5,820,177; 5,986,564; 7,051,561; D494,841; D501,131 D512,899; D519,021; D531,629; D533,009; D533,047; D533,762; D533,763; D535,629 CANADA: 1,252,854; 1,298,902
U.K. 2,010,375
Other U.S. and foreign patents pending

SAFLOK reserves the right to modify the characteristics and features of all products in this publication.
©2008 SAFLOK, all rights reserved.

© SAFLOK™        INS_QTMADESERFID – DRAFT         2/16/2012

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals