LG LRE30955S Electric Range Installation Guide

July 5, 2024
LG

LG LRE30955S Electric Range

LG LRE30955S Electric Range 

SAFETY

BEFORE YOU BEGIN

Remove all tape and packing materials before using the range.
Dispose of all plastic bags after unpacking the range. Never allow children to play with packing materials.

IMPORTANT SAFETY INSTRUCTIONS

Read and follow all instructions before using your oven to prevent the risk of fire, electric shock, personal injury, or damage when using the range. This guide does not cover all possible conditions that may occur. For further assistance contact your service agent or manufacturer.

This is the safety alert symbol. This symbol alerts you to potential hazards that can cause personal injury to you and others. All safety messages will follow the safety alert symbol with either the word “WARNING” or “CAUTION”.

WARNING This symbol will alert you to hazards or unsafe practices which could cause serious bodily harm or death.
CAUTION This symbol will alert you to hazards or unsafe practices which could cause bodily CAUTION injury or property damage.
WARNING

  • The information in this manual should be followed exactly.

    • A fire or electrical shock may result causing property damage, perasonal injury or death.
  • DO NOT step or sit on oven door. Install the Anti-Tip Bracket supplied with the range.

    • The range could be tipped and injury might result from spilled hot liquid, food, or the range itself.
    • If the range is pulled away from the wall for cleaning, service, or any other reason, ensure that the Anti-Tip Device is properly reengaged when the range is pushed back against the wall.
  • New branch-circuit installations (1996 NEC) for mobile homes, recreational vehicles, and installations where local codes do not allow grounding through the neutral wire require a 4- conductor UL listed range cord or 4 wire conduit connection.

  • The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block. The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block. Failure to do so can result in electrical shock, severe personal injury or death.

  • Only a 4-conductor power-supply cord kit rated 120/240 volts, 50 amperes and marked for use with ranges with closed-loop connectors or open-end spade lugs with upturned ends shall be used.
    The middle (neutral) wire of the power cord or 4-wire conduit has to be connected to the middle post of the main terminal block. The other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block. The 4th ground wire must be connected to the frame of the range with the ground screw.

    • Failure to do so can result in electrical shock, severe personal injury or death.

CAUTION

  • Make sure that the wall covering, countertop and cabinets around the range can withstand the heat (up to 194°F) generated by the range.
    • Discoloration, delamination or melting may occur.
    • This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194°F.
  • Cabinet storage space located above the surface units should be avoided.
  • Install a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets If cabinet storage is to be provided.
    • The risk of burns or fire by reaching over the heated surface elements can be reduced.

WARNING

  • The information in this manual should be followed exactly.
    • A fire or electrical shock may result causing property damage, perasonal injury or death.

WARNING

  • DO NOT step or sit on oven door. Install the Anti-Tip Bracket supplied with the range.
    • The range could be tipped and injury might result from spilled hot liquid, food, or the range itself.
    • If the range is pulled away from the wall for cleaning, service, or any other reason, ensure that the Anti Tip Device is properly reengaged when the range is pushed back against the wall.

NOTE

  • Read all instructions contained in these installation instructions before installing range.
  • Remove all packing materials from the oven compartments before connecting the electrical supply to the range.
  • Observe all governing codes and ordinances.
  • Be sure to leave these instructions with the consumer.

NOTE

Keep these instructions with your owner’s manual for future reference.

  • As when using any appliance generating heat, there are certain safety precautions you should follow.
  • Be sure your range is installed and grounded properly by a qualified installer or service technician.
  • Make sure the wall coverings around the range can withstand the heat generated by the range.
  • To eliminate the need to reach over the surface elements, cabinet storage space above the elements should be avoided.

PREPARE TO INSTALL THE RANGE

TOOLS NEEDED

Tools Needed

Phillips Screwdriver

Tools Needed

Flat-blade Screwdriver

Tools Needed

1/4,, Nut  Driver

Tools Needed

Pliers

Tools Needed

Level

Tools Needed

Adjustable Wrench

Tools Needed

Drill

PARTS PROVIDED

Template

Parts Provided

Anchor Sleeves

Anti-Tip Bracket Kit

Parts Provided

Lag Bolts

(For Anti-Tip Bracket Mounted on Concrete Floors and Walls)

PARTS NOT PROVIDED

Parts Not Provided

(UL Approved 40 o r 50 AMP) 4-Wire Cord OR 3-Wire Cord

Strain Relief (For Conduit Installations Only)

PREPARE TO INSTALL THE RANGE

INSTALLATION DRAWINGS

NOTE

SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR.

CLEARANCES AND DIMENSIONS (Figure 1)

To install range refer to the following Figure 1.
For installation in CANADA, a Free-standing range is not to be installed closer than 15/32 (12mm) from any adjacent surface.

CAUTION

  • Make sure that the wall covering, countertop and cabinets around the range can withstand the heat (up to 194°F) generated by the range.
    • Discoloration, delamination or melting may occur.
    • This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194°F.

Prepare To Install The Range

A = 30”(76.2 cm) For U.S.A = 30”(76.2 cm) ~ 31”(78.7 cm) For CANADA

CAUTION

  • Cabinet storage space located above the surface units should be avoided.
  • Install a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets If cabinet storage is to be provided.
    • The risk of burns or fire by reaching over the heated surface elements can be reduced.

Prepare To Install The Range

MINIMUM DIMENSIONS (Figure 2)

  • 30”(76.2 cm) minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or 24”(60.9 cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4”(6.4 cm) flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015”(0.381 mm) stainless steel, 0.024”(0.610 mm) aluminum or 0.020”(0.508 mm) copper.
  • 15”(38.1 cm) minimum between countertop and adjacent cabinet bottom.

ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTION REQUIREMENTS

This appliance must be installed and grounded on a branch circuit by a qualified technician in accordance with the National Electrical code ANSI/NFPA NO. 70 – latest edition.

All wiring should conform to Local and NEC. This range requires a single- phase, 3 wire, A.C 120/208V or 120/240V 60Hz electrical system. Use only a 3-conductor or a 4-conductor UL-listed range cord with closed loop terminals, open-end spade lugs with upturned ends or similar terminations. DO NOT install the power cord without a strain relief.

A range cord rated at 40 amps with 120/240 minimum volt range is required. If a 50 amp range cord is used, it should be marked for use with 13⁄8” diameter connection openings.

This appliance may be connected by means of conduit or power cord. If conduit is being used, go to page 7 3 wire conduit connections or page 8 for 4 wire conduit connections.

WARNING

  • New branch-circuit installations (1996 NEC) for mobile homes, recreational vehicles, and installations where local codes do not allow grounding through the neutral wire require a 4-conductor UL listed range cord or 4 wire conduit connection.

Specified power-supply-cord kit rating


Range rating, watts| Specified rating of power-supply- cord kit, amperes| Diameter (inches) of Range connection Opening
120/240 volts 3-wire| 120/208 volts 3 wire| Power cord| Conduit
8,750 – 16,500| 7,801 – 12,500| 40 or 50A| 13/8”| 11/8”
16,501 – 22,500| 12,501 – 18,500| 50| 13/8”| 11/8”

3, 4 – Wire electrical wall Receptacle

4 Wire receptacle (14-50R)

3 Wire receptacle (10-50R)

CONNECT RANGE CORD

The Rear Access cover must be removed. Loosen the three screws with a screwdriver. The terminal block will then be accessible.

Connect Range Cord 

The  ord/Conduit connection plate is used for the installation of power cord or conduit. For power cord, install it with the connection plate as INSTALLED. For conduit, remove the connection plate located below the rear of the drawer body and use the conduit hole (11 /8”) instead of power cord hole (13 /8”).
(Refer to Figure 5 and 6.)

Connect Range Cord 

Connect Range Cord 

ELECTRICAL CONNECTIONS

3-wire connection with a power supply cord

WARNING

  • The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block. The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block.
    • Failure to do so can result in electrical shock, severe personal injury or death.

Install the power cord as follows:

For power cord installations, Hook the strain relief over the power cord hole (13 /8”) located below the rear of drawer body. Insert the power cord through the strain relief and tighten it. (Refer to Figure 7.)

DO NOT install the power cord without a strain relief.

  1. Remove the lower 3 screws from the terminal block and retain them. (Refer to Figure 8.)

  2. Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block.
    Make sure that the center wire (white/neutral) is connected to the center lower position of the terminal block.

  3. Tighten 3 screws securely into the terminal block.
    Do not remove the ground strap connections.

  4. Go to page 9.

Electrical Connections

Electrical Connections

4-wire connection with a power supply cord

WARNING

  • Only a 4-conductor power-supply cord kit rated 120/240 volts, 50 amperes and marked for use with ranges with closed loop connectors or open-end spade lugs with upturned ends shall be used. The middle (neutral) wire of the power cord or 4-wire conduit has to be connected to the middle post of the main terminal block. The other two wires of the power cord o conduit have to be connected to the outside posts of the main terminal connection block. The 4th ground wire must be connected to the frame of the range with the ground screw.
    • Failure to do so can result in electrical shock, severe personal injury or death.

Follow the instructions under “ CONNECT RANGE CORD” on page 5 to correctly install the strain relief.

  1. Remove the lower 3 screws from the terminal block and retain them. (Refer to Figure 9. )
    Remove the ground screw and retain it.

  2. Remove ground strap and discard as shown in Figure 9.
    Do not discard any screws.

  3. Insert the ground screw into the power cord ground wire terminal ring and secure it to the range frame.

  4. Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block. Make sure that the center wire (white/neutral) is connected to the center lower position of the terminal block.
    Tighten 3 screws securely into the terminal block.

  5. Go to page 9.

Electrical Connections

3-wire connection: conduit

Install the conduit as follows:

Remove the Conduit connection plate from the rear of drawer body and rotate it as shown in Figure 5. The conduit hole (11 /8”) must be used.
First, prepare conduit wires as shown in Figure 10.

Electrical Connections

Second, install conduit as shown in Figure 6.
For conduit installations, after purchasing a strain relief, insert it in the conduit hole (11 /8”). Then install the conduit through the body of strain relief and fasten the strain relief with its ring. Reinstall the bracket.
For conduit connections :
If the wire in the conduit is copper it must be 8 or 10 AWG wiring.
If the wire in the conduit is aluminum it must be 6 or 8 AWG wiring.

  1. Loosen the lower 3 screws from the terminal block. (Refer to Figure 11. )

  2. Insert the bare wire (white/neutral) end through the center terminal block opening.
    Do not remove ground strap connections.

  3. Insert the two side bare wire ends into the lower left and the lower right terminal block opening.
    Tighten the 3 screws securely into the terminal block. (approximately 35 – 50 IN-LB)

  4. Go to page 9.

Electrical Connections

4-wire connection: conduit

  1. Follow the instructions under “Install the conduit as follows” on page 7 to correctly install the strain relief.
    DO NOT install the conduit without a strain relief.

  2. Loosen the 2 lower left and right screws from the terminal block. (Refer to Figure 12. )
    Remove the lower 2 center screws.

  3. Remove ground strap and discard as shown in Figure 12.
    Do not discard any screws.

  4. Attach the ground bare wire end to range frame and secure it in place with the ground screw (Refer to figure 12.)

  5. Insert the bare wire (white/neutral) end through the center terminal block opening.

  6. Insert the two side bare wire ends into the left and the right terminal block opening.
    Tighten the 3 screws securely into the terminal block. (approximately 35 – 50 IN-LB)

  7. Go to page 9

Electrical Connections

INSTALL THE RANGE

Replace the access cover on the range back. To replace the wire cover, insert double projections in the pockets located below the opening and tighten the three screws.

Install The Range

ANTI-TIP DEVICE INSTALLATION

WARNING

  • DO NOT step or sit on oven door. Install the Anti-Tip Bracket supplied with the range.
    • The range could be tipped and injury might result from spilled hot liquid, food, or the range itself.
    • If the range is pulled away from the wall for cleaning, service, or any other reason, ensure that the Anti Tip Device is properly reengaged when the range is pushed back against the wall.

Install The Range

  1. Locate the bracket using the template
    An Anti-tip bracket is packaged with template. The instructions include necessary information to complete the installation.
    Read and follow range installation instruction sheet (template).

  2. Level the range
    Level the range by adjusting the leveling legs with a wrench.

Install The Range

Use a spirit level to check your adjustments. Place the level diagonally on the oven rack, and check each direction for level.

First check direction 1 .

After check direction 2 .

Install The Range

If the spirit level doesn’t show level on the rack, adjust the leveling legs with a wrench.

FINAL INSTALLATION

  • Move range close enough to the opening to plug into the receptacle.
  • Slide range into position insuring that the left back leg slides under the anti-tip bracket. Range will sit 0” away from the back wall when properly installed.
  • Carefully tip range forward to insure that the anti-tip bracket engages the range back brace and prevents tip-over.
  • Turn on electrical power. Check range for proper operation as described in owner’s manual.

Customer Support

This Owner’s Manual is provided and hosted by Appliance Factory Parts.

Find Your LG Electric Range Parts – Select From 91 Models

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals