SEALAY BT91-7.V4 6-12V Battery Drop Tester User Manual
- June 6, 2024
- SEALAY
Table of Contents
SEALAY BT91-7.V4 6-12V Battery Drop Tester
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTUREUSE.
SAFETY
▲ DANGER! Be aware, lead acid batteries generate explosive gases during normal
battery operation, for this reason, it is very important to read and follow
these instructions carefully each time you use the battery tester. Follow
these instructions in conjunction with those of the battery and vehicle
manufacturer, and the maker of any equipment you intend to use in the vicinity
of the battery. Remember to review warning marks on all products and on
engines.
‰ WARNING! Modern vehicles contain extensive electronic systems. You are
required to check with the vehicle Manufacturer, for any specific instructions
regarding the use of this type of equipment on each vehicle. No liability will
be accepted for damage / injury, where this product is not used in accordance
with all instructions.
PERSONAL PRECAUTIONS
- ✓ Ensure there is another person within hearing range of your voice and close enough to come to your aid, should a problem arise when working near a lead-acid battery.
- ✓ Wear safety eye protection and protective clothing. Avoid touching eyes while working near battery.
- ✓ Have fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.
- ✓ Wash immediately with soap and water if battery acid contacts skin or clothing. If acid enters eye, flush eye immediately with cool, clean running water for at least 15 minutes and seek immediate medical attention.
- ✓ Remove personal metallic items such as rings, bracelets, necklaces and watches. A lead-acid battery can produce a short-circuit current which is high enough to weld a ring or the like to metal, which would cause severe burns.
- ✓ Ensure hands, clothing (especially belts) are clear of fan blades and other moving or hot parts of engine, remove ties and contain long hair.
- ✘ DO NOT smoke or allow a spark or flame in the vicinity of battery or engine.
GENERAL SAFETY
-
✘ DO NOT operate the load test switch for more than 10 seconds at a time. (Failure to release the switch after 10 seconds may
result in the switch burning out and invalidating your warranty.) -
✓ Familiarise yourself with the application and limitations of the tester as well as the potential hazards. Also refer to the vehicle manufacturer’s hand book. IF IN ANY DOUBT CONSULT AN ELECTRICIAN.
-
✓ Ensure the tester is in good order and condition before use. If in any doubt DO NOT use the unit and contact an electrician.
-
✓ Only use recommended attachments and parts. To use unapproved items may be dangerous and will invalidate your warranty.
-
✓ Ensure the tester load switch is ‘Off’ before attaching/detaching the power clamps to/from the battery terminals.
-
✓ Keep tools and other items away from the engine and ensure you can see the battery and working parts of engine clearly.
-
✓ Confirm that the battery to be tested is either 6 or 12 volt before attaching clamps to battery terminals.
-
✓ Should the unit suffer excessive shock, it must be checked by a qualified service agent before further use.
-
✓ DO NOT disassemble the tester for any reason. The tester must only be checked by qualified service personnel.
-
✓ If the battery terminals are corroded or dirty clean them with a solution ofwater and baking soda before attaching the clamps.
-
✓ Keep children and unauthorised persons away from the working area.
-
‰ WARNING! To prevent the risk of sparking, short circuit and possible explosion DO NOT drop metal tools in the battery area, or allow them to touch the battery terminals.
-
✘ DO NOT cross connect leads from tester to battery. Ensure positive (+/RED) is to positive and negative (-/BLACK) is to negative. If symbols cannot be distinguished, remember that the negative terminal is the one directly connected to the vehicle bodywork.
-
✘ DO NOT pull the cables or clamps from the battery terminals.
-
✘ DO NOT use the tester outdoors, or in damp, or wet locations and DO NOT use within the vicinity of flammable liquids or gases.
-
✓ Ensure there is effective ventilation to prevent a build-up of explosive gases, and DO NOT cover or obstruct tester ventilation louvres.
-
✘ DO NOT use the tester for a task for which it is not designed.
-
✓ When not in use, store the tester carefully in a safe, dry, childproof location.
INTRODUCTION
American-style drop tester. Load applied by internal switchgear – no sparking! Suitable for 6 and 12V batteries. Applies load across cells and measures output on meter. Accurate indication of battery voltage and faulty or short circuited cell.
OPERATION
‰ WARNING! Ensure you read, understand and apply the safety and operational instructions before connecting the tester clamps to the battery. Only when you are sure that you understand the procedures is it safe to proceed with the testing process.
PREPARATION
3.1.1. Check the battery casing for cracks or leakage and confirm whether
6 volts or 12 volts.
3.1.2. Clean the battery terminals.
3.1.3. If practical, check the electrolyte levels and top up with
distilled water as required.
CONNECTION
‰ WARNING! Ensure the vehicle or battery is in a well ventilated area
before starting to test.
3.2.1. Attach the positive red clamp to the positive (+) battery
terminal. Attach the negative black clamp to the negative (-) battery
terminal. Use the extended clamps if necessary. To ensure good electrical
contact twist the clamps on the terminals two or three times. Correct
connection indication will sweep the pointer clockwise across the voltage
scale; if connected incorrectly the pointer will sweep anti clockwise. If
there is no movement from the pointer, it is either a bad connection or a dead
battery.
3.2.2. Ensure that the clamp cables are clear of hot or moving engine parts,
especially if a starter or charging test is required. Ventilation slots in the
tester casing should not be obstructed and the meter scale easily visible with
access to the load switch.
BATTERY LOAD TEST
NOTE! On the first load test, smoke may be emitted from the louvres in
the tester casing, this is normal and temporary.
3.3.1. Press the load switch in; hold until meter reading stabilises, or
for a maximum of 10 seconds. Failure to release the switch inside 10 seconds
may result in the switch burning out and your warranty being invalidated. Note
the meter reading and then release the load switch.
3.3.2. Compare the meter reading with load test chart (3.4) to determine
battery condition.
NOTES: a) For 12 volt batteries the green sector (fig. 1A) border is
marked with nominal cranking current from 200 to 1000 amps and stepped in 200
amp intervals. Record this figure and compare with battery manufacturer’s
quoted figure to give an indication of any deterioration.
b) Battery performance falls at low temperatures and quoted cranking amps
should be reduced by 50 amps at 20ºF(-7ºC) and 100 amps at 0ºF(-18ºC).
LOAD TEST CHART
Load Test Result Fig.1 | Battery Condition |
---|---|
“OK”-Green | Battery capacity is good. May or may not be fully charged. Check |
electrolyte specific gravity to determine charge state. If not fully charged,
check for charging system fault (section 3.6) or electrical drain.
“Weak” or “Bad” -yellow or red, but pointer reading steady.| Battery capacity
is unsatisfactory. Battery may be either:- (1) defective or (2) partly
discharged. Check electrolyte specific gravity. If over 1.225, the battery is
defective. If under 1.225, recharge the battery and retest. If cell to cell
specific gravity varies by more than 0.025 a cell defect may exist. If
charging does not bring specific gravity to full charge level, the battery is
either sulphated or has lost active material.
“Weak” or “Bad” – yellow or red, but pointer reading falling after 10 seconds
on load.| Battery may be defective. Release load switch and note the meter
reaction. If the voltage recovers to 12 volts (6 volts for a 6 volt battery)
or more in a few seconds, then the battery is probably defective. If the
voltage recovers slowly the battery may only be discharged. Check the
electrolyte specific gravity and proceed as above
BATTERY VOLTAGE/CHARGE LEVEL
3.5.1. If the load test result indicates a battery fault allow battery to
stabilise for a few minutes and then read the open circuit voltage – meter
reading with load switch ‘Off’.
3.5.2. Compare the reading with the Voltage/Charge table below to get an
estimation of the charge level.
3.5.3. The battery is considered charged at 75% or more. If it failed the
load test with this charge it should be replaced. If the voltage indicates a
charge level below 75% then charge the battery and load test again. If battery
fails this second test replace it.
CHARGING SYSTEM (12 VOLT)
3.6.1. Start engine and allow to reach normal operating temperature.
Switch off all accessories.
3.6.2. Run engine at 1200 to 1500rpm and note meter reading, which should
be in the green ‘OK’ 12 Volt sector (fig.1). DO NOT press the load switch.
3.6.3. Switch on head lights and heater fan (highest speed), meter
reading should remain in the green ‘OK’ sector.
3.6.4. A reading in the red sector above “CHARGING SYSTEM” (fig.1)
indicates a fault in the charging system which will cause the battery to be
under charged. A reading in the red sector to the right (fig.1) indicates a
fault which will cause the battery to be over charged.
NOTE: Although not marked on the meter scale the ‘OK’ range for a 6 volt
charging system is 6.8 to 7.5 volts.
STARTER MOTOR (12 VOLT)
NOTE: This test requires that the battery is in good condition and is
charged to at least 75% capacity.
3.7.1. Disable ignition system; remove the fuse or similar so that engine
will not start.
3.7.2. Carry out a load test (section 3.3.), if not already done and note
voltage = reading.
3.7.3. Use the table given below or fig.1 to determine the equivalent
minimum cranking voltage. Note that for engines of less than 3.25 litres take
the next higher figure. For example:-
a) 3.5 litre engine – load test result 11.0 volts, gives min. cranking
voltage of 9.7 volts.
b) 1.5 litre engine – load test result 11.0 volts, gives min. cranking
voltage of 10.2 volts
Table:-
Load voltage 10.2 10.4 10.6 10.8 11.0 11.2 11.4
Min. cranking voltage 7.7 8.2 8.7 9.2 9.7 10.2 10.6
3.7.4. Operate the starter motor and note the voltage during cranking.
3.7.5. A reading below the minimum cranking voltage indicates that the
starter motor is taking excessive current. This may be due to poor
connections, to a faulty motor or to the battery being too small for vehicle.
3.7.6. After test reinstate ignition system.
NOTE: For a 6 volt system test as above and note load test voltage.
Double this value and determine equivalent minimum cranking voltage as in
stage 3.7.3. Halve the figure to give minimum cranking voltage for the 6 volt
system and then proceed from stage 3.7.4.
|
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging should be sorted, taken to a recycling centre and
disposed of in a manner which is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
---|---
|
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications and component parts without
prior notice. Please note that other versions of this product are available.
If you require documentation for alternative versions, please email or call
our technical team on
technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is
required for any claim
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk.
IP32 7AR
01284 757500
01284 703534
sales@sealey.co.uk
www.sealey.co.uk
© Jack Sealey Limited