Safe Space Scan Technology 3S-07TW Face Recognize and Temperature Measurement Panel User Manual

June 5, 2024
Safe Space Scan Technology

Safe Space Scan
Technology 3S-07TW Face Recognize and Temperature Measurement Panel
User Manual

Foreword
The purpose of this section is to ensure that users can use the product correctly through this manual to avoid danger or property damage during operation. Before using this product, please read the manual carefully and save it for future reference. Without written permission, no unit or individual may extract, copy, translate, or modify all or part of this manual in any way. Unless otherwise agreed, the company does not provide any express or implied statement or guarantee for this manual.

About this manual
Use this manual as a guide. The photos, graphics, diagrams, and illustrations provided in the manual are for reference only. They may differ from specific products. Please refer to the actual product. The company may update this manual due to product version upgrades or other needs. If you need the latest version of the manual, please log on to the company’s official website to check. It is recommended that you use this manual under professional person guidance

Disclaimer

  1. To the maximum extent permitted by law, the products described in this manual (including hardware, software, firmware, etc.( are provided “as is” and may have defective or errors. The company does not provide any form or Implied warranties, including but not limited to warranties of merchantability, quality satisfaction, fitness for a particular purpose, and non-infringement of third-party rights; nor does it impose any special, incidental, incidental, or indirect damages resulting from the use of this manual or the use of our products Compensation, including but not limited to loss of business profits, loss of data or documents.
  2. If you connect the product to the Internet, the product may be subject to network attacks, hackers, and virus infections. you have to bear the risk by yourself. But we will provide you with technical support in time.
  3. When using this product, please strictly follow the applicable laws. If the product is used for infringing the rights of third parties or for other improper uses, the company will not bear any responsibility. If the contents of this manual conflict with applicable laws, the legal provisions shall prevail.
    Sign convention The description of the symbols that appear in the document is shown below.

Sign Description

  1. ****Descriptive text, which supplements and explains the text.
  2. Warning texts indicate potential risks. If not avoided, they may cause injury, equipment damage, or business interruption.
  3. The dangerous text indicates that there is a high potential risk. If it is not avoided, it may cause Serious danger of personal injury or death.

Tips:
To protect your privacy and improve product security, we strongly recommend that you set a more complex password according to the following rules: 8-16 characters, consisting of two or more types of numbers, uppercase, and lowercase letters, and special characters Made.
Please understand that you are responsible for properly configuring all passwords and other related product security settings.

Chapter 1: Product Overview

Product Line Name
7-inch temperature measurement panel 7-inch temperature measurement panel

with vertical bracket
7-inch temperature measurement panel with wall bracket
8-inch temperature measurement panel| 8-inch temperature measurement panel with vertical bracket
8-inch temperature measurement panel with wall bracket

1.1 Product Introduction
The temperature measurement &Face recognized panel, using a Dual sensor with living detection, based on face recognition and infrared temperature detection. The product realizes identity confirmation and access rights management through face recognition, and also realizes non-contact temperature detection, rapid screening, automatic alarm, and automatic detection of whether the mask is worn or not.
The product avoids a manual operation, improves efficiency and reduces missing information, and reduces the hidden danger of cross-infection caused by human- to-terminal and human-to-human contact during the detection and management process. Facilitate the rapid screening of people gathering place.
Suit for hotels, access gates, office buildings, schools, shopping malls, communities, and public services.

1.2 Product Features

  1. Using high-precision infrared temperature detector non-contact automatic body temperature detection, accurate and efficient;
  2. Temperature measurement range: 30-45 ( CI, Accuracy can reach t 0.3( C 1;
  3. Real-time output of identifying results and voice prompts;
  4. Auto identify people without masks and give real-time warning;
  5. Auto register and record information, avoid a manual operation, improve efficiency and reduce missing information;
  6. Dual sensor with living detect, face recognition distance 0.3-3M,
  7. Face recognition within 500ms; Face library 22400 people. Total can storage 100,000 recognized records;
  8. Rich interface protocols, supporting SDK and HTTP protocols under multiple platforms such as Windows / Linux;
  9. Supporting machine vision optical dynamics 7 80dB, suitable for backlight environment monitor;
  10. Supports fog, 3D noise reduction, strong light suppression, electronic image stabilization, and has multiple white balance modes, suitable for various scene requirements;
  11. Linux operates the system and is more stable.

1.3 Packing list

Temperature measurement panel 1unit
Installation and user manual 1 pcs
Warranty card 1 pcs
Spare parts package Post: 1 set of waterproof network head, 6 pcs tie Wall

mount: 1 1pcs accessory kit, 1pcs gimbal bracket, 1 pcs wall mount bracket, 1 set of waterproof network head

Chapter 2: Appearance

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel -

Pigtail interface description:

No. Name Description
J1 WG OUT 1:D0 2:D1 3:GND
J2 WG IN 1:D0 2:D1 3:GND
J3 ALARM OUT RELAY SWITCH
J4 USB USB 2.0
J5 RJ45 100M
J6 DC12V POWER IN 12V/3A

| No.| Name| Description
---|---|---|---
J1| Multifunctional interface| WG OUT: Orange DO. White D1. Green GND
GW IN: Brown and white DO. Yellow D1. Gray GND
ALARM OUT: Brown ALARM+, Purple ALARM
RS485: Orange and White 485+. Blue and White 485
USB: Red 5V. Blue D-, Green and white Di-. Black GND
J2| RJ45| 100M
J3| Power supply interface| POWER IN12V/3A

Part fittings as shown :

I mage Display Name Description
Wall-mounted mounting plate 1. Divided into 7-inch and 8-inch, not

shared.
2. Standard configuration of wall-mounted temperature measurement panel.
3. Please refer to the actual size.
| Wall bracket| 1. Divided into 7-inch and 8-inch, not shared.
2. Standard configuration of wall-mounted temperature measurement panel.
3. Please refer to the actual size.
| Gimbal bracket| 1. Divided into 7-inch and 8-inch, not shared.
2. Standard configuration of wall-mounted temperature measurement panel.
3. Please refer to the actual size.
| Tripod| 1. Nonstandard, purchased by customers.
2. The recommended installation
height is less than 145mm.
| “Accessory Pack” to the tripod| 1. Standard on a tripod for fixed installations.
2. Connected with the gimbal bracket during installation.

Precautions

  1. Device working temperature: 10 C -40 C (Device optimum working temperature:16-32 C 1. Do not Install under the vent and ensure that there is no heating source within 3 meters;
  2. People entering the room from a cold outdoor environment will affect measurement accuracy. The forehead temperature test needs to be performed indoors without covering the forehead for three minutes and the temperature is stable;
  3. The temperature read by the temperature measuring device is the temperature in the forehead area. When there is water, sweat, oil or thick makeup on the forehead, or the elderly have wrinkles, the read temperature will be lower than the actual temperature. Make sure there is no hair or clothing covering this area;
  4. We suggest end-users do multi-practice for testing, be well known about testing way, detecting result can’t replace medical diagnose.

Gate installation
According to the requirements of the installation site, in the space position on the gate or on the front side, the opening diameter of the 7-inch access control machine is 30mm, and the opening diameter of the 8-inch access control machine is 35mm. The diagram is as follows:

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 7

1.2 Adjust the angle of the temperature detector
After the temperature measurement access control is fully activated, the human face is directly facing the device. Observe the face image on the device screen. Make sure that the bare skin on the forehead is placed in the “temperature measurement area” (optimal temperature detector distance 0.5mI. After that, paste the “Please stand here” detection position mark at the corresponding distance.

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 8

Note: Due to the height of the gate installation, it may cause the test personnel to actively cooperate during the test to ensure that the bare skin on the forehead is placed in the “temperature measurement area”.

2. Temporary test position, ITripod mounting)

2.1 Temperature measurement panel with vertical bracket:
Attach the cable tie from the “Accessory Pack” to the tripod for the temperature measurement access control on the column,
Temperature measurement panel with wall bracket:
Mount the gimbal bracket in the “Accessory Pack” to the tripod for the wall-mounted temperature measurement access control. Connect the power supply and network cable.
2.2 Adjust to the best angle and detection position of the detector, as image below:

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 10

2.3 After temperature detection is confirmed, make detect position mark on the ground for accurate detection.
Note: There is no need to move or adjust the relevant position or height after installation is completed. Due to the height difference of the inspected person, the inspected person may need to cooperate actively to ensure the accuracy of the inspection data.
3. Wall mounting
Note:
The installation height of 1.5 meters here is the recommended installation height, and users can adjust it according to their height.

Installation with 86 boxes

Step 1: Make holes in the wall according to the mounting bracket and install 86 boxes.
Step 2: Use a special tamper-proof wrench to loosen the tamper-resistant fixing screws at the bottom of the device, remove the mounting plate, and The hanging plate is fixed on the 86 box as shown below.
Step 3: Hang the device from top to bottom on the mounting plate.
Step 4: Use a special tamper wrench at the bottom of the device to lock the tamper screws.

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 11

Installation without 86 boxes:

Step 1: Fix the mounting base on the mounting wall as shown in the figure below.
Step 2: Use a special tamper-proof wrench to loosen the tamper-resistant fixing screws at the bottom of the device, remove the mounting plate, and lock it to the mounting base plate according to the hole position.
Step 3: Hang the device from top to bottom on the mounting plate.
Step 4: Use a special tamper wrench at the bottom of the device to lock the tamper screws.

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 12

Chapter 4: Instructions

4.1 IE page setup and environment setup
In an environment where all aspects of the device and network work normally, open the IE browser, Input the device IP in the address bar, OP defaults is 192.168.1.88], press Enter button, pop up login interface, input password: admin, Click Login.

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 13

4.2 Setting
4.2.1 System Info
4.2.1.1 Language config, select the desired language

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 14

4.2.1.2 User management, password setting

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 154.2.1.3 System Time

2.1.4.2 Wireless network parameter setting
Click “Scan” to search for a nearby wireless network, select the target network, then enter a password, and click the save button, when connecting success, the device IP will show on the LCD monitor. So please disconnect the RJ45 network cable from the device.
If you want preview details for the device, pls Input the device 1131 IP shown on the LCD monitor Jon the browser, then pop up the login interface, so can preview. Please notice that the PC should be at the same IP segment as the device, the PC connects to the same router.
(Note: wired network and wireless connection will not have the same IP address)

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 17

4.2.2 Face recognition-Access control

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 18

4.2.2.1 White light control
Set the light status according to the actual environment ( default is to turn off when detects no person).

4.2.2.2 Screen display mode
Set the display mode according to the usage (default is closed when detects no person).
4.2.2.3 Temperature threshold
The temperature threshold can be set between 35-45 C, the default value is 37.3 C, and can be modified according to actual user needs.
4.2.2.4 Temperature correction
“Smart Algorithm” defaults mode is “Smart Algorithm” under this mode no correction value;
“Low-temperature algorithm” mode operation method, choose to use correction method in the environment with low ambient temperature (below 10 C ); a. Prepare a forehead temperature gun that meets relevant national standards;
b. On-site temperature calibration requires the cooperation of two persons who are in good health (without fever and fever), one person is responsible for the operation, and the other acts as the person under test;
c. Use the forehead temperature gun to test the forehead temperature of the person under test. It is recommended to make multiple (3-5 times) Multi- time measurements to ensure temperature values accuracy is less than 0.3 C, record the measured temperature value, and then use the temperature measurement access control machine to test the person. After subtracting the average value measured by the access control machine from the average value measured by the forehead gun, fill in the “temperature In the “Compensation” box, and click “Save”. After saving the parameters, perform the test. The above method is set only when the value of the temperature gun and the access control machine are basically the same (the error range is less than 0.3 C).
4.2.2.5 Temperature measurement mode
Temperature measurement mode can choose precise temperature measurement or fast measurement mode (default is accurate measurement mode).
4.2.2.6 Temperature measurement unit
Set temperature threshold/temperature unit according to usage habits (default is Celsius, 37.3 C ).
4.2.2.7 Temperature abnormal switch control
This item’s default is” turn off”. It is set according to actual needs. After the setting is turned on, when the measured forehead temperature is too high, or too low, the door switch signal will be triggered. In actual application, this switch signal can be to connect the alarm device, when detecting temperature abnormal, and have an alarm voice output.
4.2.2.8 Comparison record storage
According to actual needs, the comparison information will be stored on the device when the face recognition is turned on, and the record will still exist after the power is turned off.
4.2.2.9 Mask temperature detection
Mask temperature detect” can choose “no temperature detection”, “mask detection”, “mask + body temperature detection” and other modes, when “no” is selected, the temperature will not be measured, after selecting “body temperature detection” mode, the temperature will be measured, and select “mask detection” “Mode detects that no mask is worn, it will prompt remind voice” please wear a mask “. Selecting the” body temperature + mask detection “mode will detect when wearing the mask and measure temperature.

Mask temperature detection

4.2.2.10 Open door setting
This setting can be used in combination with the “mask temperature detection setting”, or can be set separately.

Opening ConditionsSafe Space Scan Technology 3S 07TW Face Recognize and
Temperature Measurement Panel - 21

4.2.2.11 Control interface
Set the interface control mode, including the Wiegand interface and alarm out interface. Wiegand interface + switching value.

Control interface

4.2.2.12 Open state
This setting can be set to normally open or normally closed according to the actual application.
4.2.2.13 Wiegand protocol
Wiegand output: When you need to use the Wiegand interface, select the corresponding protocol according to an external device, we support WG 26 / WG 34 protocol.
4.2.3 Face recognition • Parameter setting
4.2.3.1 Switch
This item is used to enable the face recognition algorithm. Only when the switch is open, the face recognition capture be performed, and other parameter settings will take effect.

4.2.3.2 Arming time
This item is arming time. The user can define two time periods. To make it effective, check the box next to [Arming time period]. Default: Both time periods are enabled, the default time is 00: 00 – 23: 59.
4.2.3.3 Sensitivity
Setting range: 0 -10. The default sensitivity is 9.
The sensitivity values are higher, the capture image quality be worse The sensitivity Values are lower, and The capture image quality will be better.

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 24

4.2.3.4 Snapshot Mode
Snapshot mode: The access control machine default to [Single mode] [Single mode]: Used with [Interval Frames], the default [Snapshot Times] is 8 and [Interval Frames] is 5 frames.

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 25

Description: Trial scene access control and gate. When multiple people pass the gate, only the front person can be captured (the face pixel is the largest in the picture). There is only one face square in the picture.
4.2.3.5 Maximum and minimum pixels for face recognition

  1. Face recognition maximum pixel setting range: 300-500. Default: 500.
  2. Face temperature measurement minimum pixel setting range: 0-500.Default: 300
  3. Face recognition minimum pixel setting range: 30 – 300. Default: 130
  4. When the face’s pixels in the frame are less than 130 (the smallest pixel for face recognition), they are not captured; when the face’s pixels in the frame are greater than 500 (the largest pixel for face recognition), they are not captured.

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 26

4.2.3.6 Face Scene
This parameter setting is used to adopt different face exposure strategies for different application scenarios. There are two modes of the ordinary scene and lobby scene. The default is [Lobby Scene]. Ordinary scene: used in the normal environment; lobby scene: suitable for the backlit environment.

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 27

4.2.3.7 Face Tracking Frame
This parameter is used to overlay the face tracking frame. [Open] by default.

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 28

4.2.3.8 Living detect
This parameter is used for live detection. The default state is [On].

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 29

4.2.4 List management
This parameter is used to add a face library list, divided into white and VIP lists.
List management: through “Add List”, select the face image to add; as a snapshot below:

Step 1: Click Browse and select the face image to be imported;
Step 2: Select the type of list library (white list, VIP list), input the name, and fill in the face image information;
Step 4: Click”Save”
Batch import: Add face image through batch import, as shown below:

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 31

Step 1: Click Browse, according to the storage path Ctrl + A select all or press Ctrl + mouse to select the face image to be imported;
Step 3: Select the type of list library (white list, VIP list);
Step 4: Click”Save”
Picture name, numbering rules: Picture name + picture numbers can not be repeated, a single item can be repeated, ID number and mobile phone number can be optional. (Delete the face list and double-click to delete the face image to be deleted).
4.2.5 Attendance and Comparison record
4.2.5.1 Comparison record
You can check the latest 100,000 recognize records; you can check the complete recognition or details person’s recognize record.

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 32

Checking mode:

  1. Time period checking: you can enter any time period to query the comparison records in the specified time period;
  2. List checking: select any list to query the comparison records of the specified list;
  3. Name and Number checking: You can enter the name and number of any person who already exists for a specific query.

4.2.5.2 Attendance settings and attendance records
4.2.5.2.1 Attendance setting

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 33

a. Click “set Time” to select the working day to be set, set the commute time, and save it.
b. Click “Advanced Settings” to choose single or multiple working days, set the working time, and save it.
4.2.5.2.2 Attendance record query
Attendance records can be queried; attendance results can be queried by day, time period, late arrival, early departure, non-attendance, etc., and attendance results can also be queried by specific name number. (Note: The attendance status can only be recorded when the door opening condition is set to “white list + …” mode).
4.3 Restore
4.3.1 Restore factory setting, select the desired restore to factory state

4.4 Reboot

4.5 Device Setting

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 36

(This item can be used to clear all the face images and comparison records/attendance records of the device list library)
4.6 Audio attributes setting
4.6.1 This parameter is used to set sound voice size and turn off / on sound

7″ access control panel diagram:

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 38

8″ access control panel diagram :

Safe Space Scan Technology 3S 07TW Face Recognize and Temperature
Measurement Panel - 39

FCC Warning:

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals