HOSHIZAKI FM-1000AKE Modular Ice Maker Instruction Manual

June 17, 2024
HOSHIZAKI

HOSHIZAKI FM-1000AKE Modular Ice Maker

HOSHIZAKI-FM-1000AKE-Modular-Ice-Maker-product

Product Information

Specifications

  • Model: FM-480AKE
  • Product Type: Modular Ice Maker
  • Power Supply: Corded
  • Construction: Top Panel, Front Panel, Operation Panel, Air Filter, Louver
  • Accessories Included: Mounting Bracket, Power Supply Cord, Braided SS Inlet Hose, Outlet Hose, Dual Check Valve, Connector Cover

Product Usage Instructions

Installation Instructions

  1. Ensure that the installation is carried out by qualified personnel according to current regulations and the manufacturer’s instructions.
  2. Keep ventilation openings in the appliance enclosure or built-in structure clear of obstructions.

Unpacking
Before unpacking the product, please note the following safety instructions:

  • Keep children away from the packaging elements (plastic bags and expanded polystyrene) as they can be potential sources of danger.
  • Do not lift or maneuver the carton using the shipping bands.
  • When moving the unit by hand, remove the panels and hold the unit frame.
  • Always wear protective gloves when carrying the unit.
  • When handling the carton or the unpacked unit, work in pairs to prevent injury.

FAQ

  • Can this ice maker be used for residential purposes?
    No, this ice maker is designed for commercial use only. Using it for any other purpose is considered improper and dangerous.

  • What accessories are included with the product?
    The accessories included are a mounting bracket, power supply cord, braided SS inlet hose, outlet hose, dual check valve, and connector cover.

IMPORTANT SAFETY INFORMATION

Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit.

WARNING| Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
---|---
CAUTION| Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE| Indicates a hazardous situation which, if not avoided, could result in damage to the unit.
HYGIENE| Indicates important precautions for hygiene and food safety.
IMPORTANT| Indicates important information about the use and care of the unit.
IMPORTANT

This booklet is an integral and essential part of the product and should be kept and preserved by the user.
Please read carefully the guidelines and warnings contained herein as they are intended to provide the installer/user with essential information for the proper installation and the continued safe use and maintenance of the product.
Please preserve this booklet for any further consultation that may be necessary.
WARNING

This is a commercial icemaker and should be destined only to be used for the purpose for which it has been expressly designed.

Any other use should be considered improper and therefore dangerous. The manufacturer will not be held liable or responsible for any damage caused by improper, incorrect and unreasonable use.

The installation, and relocation if necessary, must be carried out by qualified personnel , under current regulations, according to the manufacturer’s instructions.
Keep ventilation openings, in the appliance enclosure or the built-in structure, clear of obstruction.

The use of any electrical appliance involves the observance of some fundamental rules. In particular:

  • Instances of high humidity and moisture increase the risk of electrical short circuits and potential electrical shocks. If in doubt, disconnect the icemaker.
  • Do not damage the power cord or pull it to disconnect the icemaker from the electrical supply network.
  • Do not touch the electrical parts or operate the switches with damp hands.
  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be done by children without supervision.
  • Do not attempt to modify the icemaker. Only qualified personnel may disassemble or repair the appliance.

INSTALLATION INSTRUCTIONS

CONSTRUCTION
ACCESSORIES
CD 1
Mounting Bracket 2
Power Supply Cord 1
Braided SS Inlet Hose 1
Outlet Hose 1
Dual Check Valve 1
Connector Cover 1

HOSHIZAKI-FM-1000AKE-Modular-Ice-Maker-fig- \(2\)

UNPACKING

WARNING

Children should not be allowed in reach of the packaging elements (plastic bags and expanded polystyrene) as they are potential sources of danger.
CAUTION

Do not lift or manoeuvre the carton by using the shipping bands.
When moving the unit by hand, remove the panels and hold the unit frame.
Always wear protective gloves when carrying the unit.
When handling the carton or the unpacked unit, work in pair to prevent injury.
NOTICE

Remove shipping carton, tape(s) and packing. If packing material is left in the icemaker, it will not work properly.

This icemaker needs a storage bin. The recommended storage bin is HOSHIZAKI ICE STORAGE BIN, Model B-300SD(PD) or B-500SD(PD) with top kit – 8C, B-700SD(PD) with top kit – 22C, or B-900SD(PD) with top kit – 22C and top kit -8C.

  1. After removing the packaging, make sure that the icemaker and the storage bin are in good condition. If in doubt, please do not use the icemaker but apply to professionally qualified personnel. See the instruction sheet attached to the storage bin for its unpackaging and installation guidelines.

  2. Remove the shipping tape holding panels.

  3. Remove the front, top, and side panels.

  4. Remove the package of accessories. Check the contents according to “2. ACCESSORIES”.

    • Top Panel: Remove the screw. Lift off.
    • Front Panel: Remove the screw. Lift up and pull toward you.
    • Side Panel: Remove the screws. Pull slightly toward you.
  5. Remove the protective plastic film from the panels. If the icemaker is exposed to the sun or to heat, remove the film after the icemaker cools.

LOCATION

WARNING

This icemaker is not intended for outdoor use.
The ice maker should not be located next to ovens, grills or other high-heat- producing equipment.
This appliance is not suitable for installation in an area where a water jet could be used.
CAUTION

The location should provide a firm and level foundation for the icemaker.
NOTICE

Do not place anything on top of the ice maker or in front of the louvre.
IMPORTANT

Normal operating ambient temperature should be within 5°C to 40°C. The water connection is cold water only. Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect production capacity.
Allow the clearance specified below for proper air circulation and ease of maintenance and/or service should they be required.

HOSHIZAKI-FM-1000AKE-Modular-Ice-Maker-fig- \(4\)

In some high-humidity environments, condensation may form inside the machine and drip onto the floor. Do not install where the floor can be affected by water.

INSTALLATION

CAUTION

Incorrect installation can cause harm to people, animals or other items, for which the manufacturer cannot be held responsible.

  1. Fully screw in the four legs provided (bin accessory) into the storage bin underside.

  2. Position the storage bin on the selected permanent side.
    [Except FM-170]

  3. Remove the tape from the chute opening at the bottom of the icemaker.
    [Except FM-170]

  4. Pull down the end of the string coming out of the chute opening to remove the cushion.
    Note: If the power supply is turned on with the cushion left inside, the icemaker will not start showing “BIN FULL” in the display.

  5. Place the icemaker on top of the storage bin by holding the bottom.HOSHIZAKI-FM-1000AKE-Modular-Ice-Maker-fig- \(5\)

  6. Secure the icemaker to the storage bin, by using the two mounting brackets and two bolts provided.

  7. Seal the seam between the icemaker and the storage bin with food-grade sealant.

  8. Refit the side panels in their correct position.

  9. Adjust the four legs on the bottom (adjustable from 0 to 25.4 mm) to have the icemaker perfectly horizontal. Use the spirit level.HOSHIZAKI-FM-1000AKE-Modular-Ice-Maker-fig- \(6\)

ELECTRICAL CONNECTIONS

WARNING

THIS APPLIANCE MUST BE EARTHED

Electrical connections must be made by the appropriate local codes and regulations. The ice maker is to be

connected to a residual-current device-protected, earthed wall socket via the supplied flexible supply cord.

Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.

  • It is recommended that these appliances are connected to a separate 240VAC supply, protected by an appropriate circuit breaker and Residual Current Device. Check the nameplate on the icemaker for the supply requirements.
  • The main control box fuse is rated 3A and should only be replaced by a qualified service engineer.
  • The service of a licensed electrician may be required to ensure the installation is per the local codes and regulations.

[FM-1000, 600]

  • If the supply cord and/or the plug should need to be replaced, it should only be done by a qualified service engineer.
  • The fixed wiring must incorporate a means for disconnection from the supply having a contact separation of at least 3 mm in all poles.

[FM-750, 480, 300,170]

  • If the supply cord is damaged, it must be replaced by a replacement cord available from Hoshizaki Parts/Service Centres.
  • The wires in the mains lead are coloured following the following code:
    • Green & Yellow = Earth
    • Blue = Neutral
    • Brown = Live

WATER SUPPLY AND DRAIN CONNECTIONS

WARNING
Connect to potable cold water supply only.

  • The service of a licensed plumber may be required to ensure the installation is according to the local codes and regulations.

[Connection to the water supply]

  • The connections to the mains water supply must be made by the Plumbing Code of Australia and by AS / NZS 3500.1 and AS / NZS 3500.2. The dual check valve (backflow prevention) supplied with this unit must be connected between the main supply outlet and the water inlet of the ice maker.
  • Icemaking water must be potable water. Where scaling can be caused by water quality, installation of an external filter or softener is recommended. Contact your local water treatment professional or Hoshizaki service agent.
  • Water supply pressure should be a minimum of 0.05 MPa (0.5 bar) and a maximum of 0.8 MPa (8 bar). If the pressure exceeds 0.8 MPa (8 bar), use a proper pressure-reducing valve. Do NOT throttle back the supply tap.HOSHIZAKI-FM-1000AKE-Modular-Ice-Maker-fig- \(7\)
  • The dual check valve must be connected in the icemaker water supply between the main water supply outlet and the straight connection of the braided stainless steel inlet hose as shown.
  • Attach the angled end of the braided stainless steel inlet hose to the G3/4” water inlet fitting on the rear of the ice maker.
  • Be sure to use the new inlet hose sets supplied with the appliance. Do not reuse any other inlet hose set.
  • Ensure rubber tap washers are correctly positioned. Hand-tighten the dual check valve and inlet hose sufficiently to provide a leak-free joint.

Connection to the drain

  • Hand-tighten the grey flexible outlet hose (accessory) onto the R3/4 fitting on the rear of the icemaker as indicated, ensuring the rubber washer is correctly positioned to obtain a leak-free joint. The hose can be cut to length as necessary to suit the position of the main drain.
  • Drain lines should not be installed directly into the sewer system. A vertical air gap of a minimum of 5 cm should be between the end of the drain hoses from the icemaker and storage bin and the floor drain.
  • To prevent a backflow into the storage bin, the outlet hose must be laid as shown.HOSHIZAKI-FM-1000AKE-Modular-Ice-Maker-fig- \(9\)

OPERATING INSTRUCTIONS

CAUTION
Do not step into the storage bin, or put your hands into the machine compartment inside the storage bin. Children can get trapped inside, or the icemaking mechanism may suddenly move, resulting in injury.

NOTICE

All parts are factory-adjusted. Improper adjustments may result in failure.
If the unit is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.
HYGIENE

This icemaker is designed to produce edible ice. To keep the icemaker hygienic:

  • Wash your hands before removing ice. Use the plastic scoop provided (accessory).

  • The storage bin is for ice use only. Do not store anything else in the bin nor use other electrical appliances in the bin.

  • Clean the storage bin before use (see “III. 1. CLEANING”).

  • Keep the scoop clean. Clean it by using a neutral cleaner and rinse thoroughly.

  • Close the door after removing ice to prevent the entrance of dirt, dust or insects into the storage bin.

STARTUP

The installer will normally commission the icemaker to start the automatic icemaking process. To ensure continuous operation, make sure that:

  • The water supply tap is on, and
  • The icemaker is connected to the power supply.
  • To start the icemaking process, check the position of the operation switch on the operation panel:
  • “OFF” position – Move it to the “ON” position.
  • “ON” position – Press the ice button.

SHUT DOWN
Push the stop button on the operation panel. The display will blink in the “STOP” mode for 15 minutes during the drain control operation and will start to illuminate constantly at the end of drain control.

PREPARING THE ICEMAKER FOR LONG STORAGE

NOTICE

This icemaker will not work at subfreezing temperatures. To prevent damage to the water supply line, drain the icemaker when air temperature is below zero.
HYGIENE

When shutting down the icemaker for two or more days, drain the icemaker to prevent contamination in the water circuit.

  1. Follow the instructions in “2. SHUT DOWN”.
  2. Close the water supply line shut-off valve.
  3. Open the drain valve.
  4. Press the ice button on the operation panel to drain the water circuit.
  5. When no more water comes out of the drain valve, press the stop button.
  6. Move the operation switch to the “OFF” position, and disconnect the power supply.
  7. Close the drain valve.
  8. Remove all ice from the storage bin, and clean the bin.

MAINTENANCE

CLEANING

WARNING

Before carrying out any cleaning or maintenance operations, unplug the icemaker from the electrical supply network.
This appliance must not be cleaned by use of a water jet.
CAUTION

When using a neutral cleaner or sodium hypochlorite, thoroughly read and understand the instructions provided to prevent potential health problems.
NOTICE

Ask a trained service person to clean and sanitize the icemaker water system at least twice a year and to check and clean the condenser at least once a year.
To prevent possible damage, do not clean the plastic parts with water above 40°C or in a dishwasher.

Machine and Bin Exterior
Wipe the exterior at least once per week with a clean, soft cloth. Use a damp cloth containing a neutral cleaner to wipe off grease or dirt.

Scoop and Storage Bin Handle Cleaning/Sanitisation (Daily)

  1. Either mix 1 litre of water with 4 ml of 5.25% sodium hypochlorite solution in a suitable container, or the recommended Hoshizaki sanitiser as directed.

  2. Soak the scoop in the solution for more than 3 minutes. Rinse thoroughly, and shake to remove surplus liquid.
    Note: Using a cloth to dry may re-contaminate.

  3. Use a neutral cleaner to wash the storage bin handle. Rinse thoroughly.

  4. Soak a clean cloth with the sanitising solution, and wipe the handle. Use fresh water and a clean cloth to rinse/dry.

Storage Bin Interior Cleaning/Sanitisation (Weekly)

  1. Open the storage bin door, and remove all ice.
    Note: Hoshizaki recommends various types of storage bins for the icemaker which vary in size and design. The following instructions are therefore for general guidance only.

  2. Remove the thumbscrews securing the baffle.

  3. Remove the baffle from the bin.

  4. Wash the bin liner, and baffle with a neutral non-abrasive cleaner. Rinse thoroughly.

  5. Either mix 5 litres of water with 18 ml of 5.25% sodium hypochlorite solution in a suitable container, or the recommended Hoshizaki sanitiser as directed.

  6. Soak a clean sponge or cloth with the solution, and wipe the bin liner surfaces, and baffle.

  7. Refit the baffle and thumbscrews. Wipe the surface of the bin door and thumbscrew with the solution. Close the bin door.

  8. The remaining solution can be used to sanitise utensils.

Note: Do not wipe dry or rinse after sanitising, but allow to air dry.

Storage Bin Door
Clean the storage bin door at least once a week, using a neutral non-abrasive cleaner. Rinse thoroughly after cleaning and sanitise as required.

Air Filter
Plastic mesh air filters remove dirt or dust from the air and keep the condenser from getting clogged. If the filters get clogged, the icemaker’s performance will be reduced. Remove and clean the air filter(s) at least twice per month:

  1. Slide the air filter off the louver.
  2. Clean the air filter by using a vacuum cleaner. When severely clogged, use warm water and a neutral cleaner to wash the air filter.
  3. Rinse and dry the air filter thoroughly.

NOTICE
After cleaning, be sure to place the air filter back in position.

INSPECTION AND MAINTENANCE

NOTICE

To achieve optimum icemaker performance, the following parts need periodic inspection and maintenance: Extruding head (upper bearing)

Housing (lower bearing) Mechanical seal

  • These parts should be inspected after two years from installation or 10,000 hours of operation, whichever comes first, and once a year afterwards. Replacement of these parts is required if wear exceeds factory recommendations.
  • Their service life, however, depends on water quality and the environment. More frequent inspection and maintenance are recommended in bad or severe water conditions.
  • Consult with your local Hoshizaki service agent about inspection and maintenance services.

BEFORE CALLING FOR SERVICE

WARNING
Do not damage the refrigerant circuit.

Error Code Indication
If the error code “E” is indicated on the display, before calling for service, check the following.

Code Remedy
E0 Possibility of water leaks. Turn OFF the operation switch, and turn

it ON again. If the error code appears again, call for service.
E1| Low ice production. Turn OFF the operation switch, and turn it ON again. If the error code appears again, call for service.
E2| Water supply circuit failure. Turn OFF the operation switch, and turn it ON again. If the error code appears again, call for service.
E3| Gear motor failure. Turn OFF the operation switch, and turn it ON again after 10 minutes. If error code appears again, call for service.
E4| Abnormal high-side pressure. Clean air filter. Check that the icemaker is properly installed according to the installation manual.

Turn OFF the operation switch, and turn it ON again. If the error code appears again, call for service.

E5| Electric circuit failure. Turn OFF the operation switch, and turn it ON again. If the error code appears again, call for service.
E8| The compressor could be overheated. Check that the icemaker is properly installed according to the installation manual. Turn OFF the operation switch, and turn it ON again after 10 minutes. If the error code appears again, call for service.
---|---
EA| Electric circuit failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
---|---
Eb| Electric circuit failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
EC| Electric circuit failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
EE| Gear motor failure. Turn OFF the operation switch, and turn it ON again. If the error code appears again, call for service.
EF| The supply voltage is too low. Check that the voltage is in the required range and icemaker is not sharing a single receptacle with other appliances. Turn OFF the operation switch, and turn it ON again. If the error code appears again, call for service.
EH| Electric circuit failure. Turn OFF the operation switch, and turn it ON again. If the error code appears again, call for service.
EL| The Bin control switch has failed. Turn OFF the operation switch, and turn it ON again. If the error code appears again, call for service.
En| Electric circuit failure. Turn OFF the operation switch, and turn it ON again. If the error code appears again, call for service.
EU| Controller board failure. Turn OFF the operation switch, and turn it ON again. If the error code appears again, call for service.

No Error Code Indication
If the ice maker does not work properly or does not work at all and no error code is indicated on the display, before calling for service, check that:

  • The power is supplied to the unit.
  • The water is turned on.
  • The air filter is clean.

For further assistance or advice, contact your local Hoshizaki service agent.

DISPOSAL
Comply with local regulations regarding the disposal of this appliance and its refrigerant gas. Before you scrap the appliance, take off the door to prevent children trapped.

Correct disposal of this product:
This marking indicates that this product should not be disposed of with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

WARRANTY

Hoshizaki warrants to the original owner/user that all Hoshizaki branded products shall be free of defects in material and/or workmanship for the duration of the “warranty period”. The warranty shall be effective for two years from the date of installation. Hoshizaki’s liability under the terms of the warranty are limited and shall exclude routine servicing, cleaning, essential maintenance and/or repairs occasioned by misuse and installations, not per Hoshizaki guidelines.

Warranty repairs should be completed by an approved Hoshizaki dealer or service agency using genuine Hoshizaki components.

To obtain full details of your warranty and approved service agency, please contact your dealer/supplier, or the nearest Hoshizaki Service office:

Hoshizaki Lancer

  • TEL: +61 8 8268 1388
  • FAX: +61 8 8268 1978

SPECIFICATIONS

Model FM-1000AKE FM-1000AKE-N FM-750AKE
Type Air-cooled, flake ice Air-cooled, nugget ice Air-cooled, flake ice
Power Supply 1 phase 220-240V 50Hz 1 phase 220-240V 50Hz 1 phase 220-240V

50Hz
Electric Consumption| 2490W| 2550W| 1880W
Ice Production per 24h| 1030kg

(ambient 10°C, water 10°C)

| 860kg

(ambient 10°C, water 10°C)

| 750kg

(ambient 10°C, water 10°C)

Dimensions| 762mm(W) x 700mm(D) x 780mm(H)| 762mm(W) x 700mm(D) x 780mm(H)| 762mm(W) x 700mm(D) x 780mm(H)
Refrigerant| R404A, 1350g| R404A, 1350g| R404A, 1200g
Weight| Net: 146kg (Gross: 156kg)| Net: 146kg (Gross: 156kg)| Net: 133kg (Gross: 143kg)
Ambient Temp| 5 – 40°C| 5 – 40°C| 5 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.05 – 0.8 MPa (0.5 – 8 bar)| 0.05 – 0.8 MPa (0.5 – 8 bar)| 0.05 – 0.8 MPa (0.5 – 8 bar)
Voltage Range| Rated voltage ± 10%| Rated voltage ± 10%| Rated voltage ± 10%
Model| FM-750AKE-N| FM-600AKE| FM-600AKE-N
---|---|---|---
Type| Air-cooled, nugget ice| Air-cooled, flake ice| Air-cooled, nugget ice
Power Supply| 1 phase 220-240V 50Hz| 1 phase 220-240V 50Hz| 1 phase 220-240V 50Hz
Electric Consumption| 2010W| 1900W| 1950W
Ice Production per 24h| 590kg

(ambient 10°C, water 10°C)

| 600kg

(ambient 10°C, water 10°C)

| 530kg

(ambient 10°C, water 10°C)

Dimensions| 762mm(W) x 700mm(D) x 780mm(H)| 560mm(W) x 700mm(D) x 780mm(H)| 560mm(W) x 700mm(D) x 780mm(H)
Refrigerant| R404A, 1200g| R404A, 1300g| R404A, 1300g
Weight| Net: 133kg (Gross: 143kg)| Net: 107kg (Gross: 114kg)| Net: 107kg (Gross: 114kg)
Ambient Temp| 5 – 40°C| 5 – 40°C| 5 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.05 – 0.8 MPa (0.5 – 8 bar)| 0.05 – 0.8 MPa (0.5 – 8 bar)| 0.05 – 0.8 MPa (0.5 – 8 bar)
Voltage Range| Rated voltage ± 10%| Rated voltage ± 10%| Rated voltage ± 10%
Model| FM-480AKE| FM-480AKE-N| FM-300AKE
---|---|---|---
Type| Air-cooled, flake ice| Air-cooled, nugget ice| Air-cooled, flake ice
Power Supply| 1 phase 220-240V 50Hz| 1 phase 220-240V 50Hz| 1 phase 220-240V 50Hz
Electric Consumption| 1650W| 1650W| 1000W
Ice Production per 24h| 500kg

(ambient 10°C, water 10°C)

| 430kg

(ambient 10°C, water 10°C)

| 320kg

(ambient 10°C, water 10°C)

Dimensions| 560mm(W) x 700mm(D) x 780mm(H)| 560mm(W) x 700mm(D) x 780mm(H)| 560mm(W) x 700mm(D) x 780mm(H)
Refrigerant| R404A, 600g| R404A, 600g| R404A, 460g
Weight| Net: 95kg (Gross: 102kg)| Net: 95kg (Gross: 102kg)| Net: 80kg (Gross: 87kg)
Ambient Temp| 5 – 40°C| 5 – 40°C| 5 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.05 – 0.8 MPa (0.5 – 8 bar)| 0.05 – 0.8 MPa (0.5 – 8 bar)| 0.05 – 0.8 MPa (0.5 – 8 bar)
Voltage Range| Rated voltage ± 10%| Rated voltage ± 10%| Rated voltage ± 10%
Model| FM-300AKE-N| FM-170AKE| FM-170AKE-N
---|---|---|---
Type| Air-cooled, nugget ice| Air-cooled, flake ice| Air-cooled, nugget ice
Power Supply| 1 phase 220-240V 50Hz| 1 phase 220-240V 50Hz| 1 phase 220-240V 50Hz
Electric Consumption| 1000W| 600W| 620W
Ice Production per 24h| 270kg

(ambient 10°C, water 10°C)

| 170kg

(ambient 10°C, water 10°C)

| 160kg

(ambient 10°C, water 10°C)

Dimensions| 560mm(W) x 700mm(D) x 780mm(H)| 560mm(W) x 700mm(D) x 780mm(H)| 560mm(W) x 700mm(D) x 780mm(H)
Refrigerant| R404A, 460g| R134a, 390g| R134a, 390g
Weight| Net: 80kg (Gross: 87kg)| Net: 68kg (Gross: 75kg)| Net: 68kg (Gross: 75kg)
Ambient Temp| 5 – 40°C| 5 – 40°C| 5 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.05 – 0.8 MPa (0.5 – 8 bar)| 0.05 – 0.8 MPa (0.5 – 8 bar)| 0.05 – 0.8 MPa (0.5 – 8 bar)
Voltage Range| Rated voltage ± 10%| Rated voltage ± 10%| Rated voltage ± 10%

Note: The above specifications are for the representative models.

This product includes a hermetically sealed refrigeration system that contains fluorinated greenhouse gases covered by the Kyoto Protocol:

FM-1000AKE(-N) R404A / GWP 3920 / 1.350kg FM-480AKE(-N)             R404A / GWP 3920 / 0.600kg FM-750AKE(-N) R404A / GWP 3920 / 1.200kg                             FM-300AKE(-N) R404A / GWP 3920 / 0.460kg FM-600AKE(-N)             R404A / GWP 3920 / 1.300kg                             FM-170AKE(-N)             R134a / GWP 1430 / 0.390kg

This product is insulated with foam blown with fluorinated greenhouse gases.


This product meets the essential health and safety requirements demanded by the following regulations:

EMC Directive (2004/108/EC)

Low Voltage Directive (2006/95/EC) RoHS Directive (2011/65/EU)

Food Contact Materials Regulation (EC 1935/2004)

Manufacturer:     Hoshizaki Europe Ltd.

Telford 70 Stafford Park 7, Telford, Shropshire TF3 3BQ England


References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>