PROPANE FORCED AIR HEATER
User’s Manual & Operating Instructions
MODEL NUMBERS: 60VMHD-GFA / 150VMHD-GFA
CONSUMER: READ AND RETAIN THESE INSTRUCTIONS FOR FUTURE USE
60VMHD-GFA Propane Forced Air Heater
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of
your heater. It will begin with the letter “G” followed by 9 digits. For
Example: G123456789. Have your Serial Number ready before calling customer
service at 800-641-6996.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS
HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE
FROM HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON MONOXIDE POISONING
AND / OR ELECTRIC SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR
SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN
INSTRUCTIONS MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS.
Factory ID: 500
Sauk Rapids, MN 56379 USA · Toll Free
800-641-6996
Fax: 320-251-2922 · Web:
www.masterindustrialproducts.com ·
Email: info@pinnacleclimate.com
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE
SAFETY INFORMATION
Carbon Monoxide Hazard This heater produces carbon monoxide, which has no
odor. Burning the heater in an enclosed space can kill you. Never use the
heater in enclosed spaces such as a tent, a camper, any vehicle or
recreational vehicle (RV), enclosed shelter, or any other enclosed areas.
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
Not for use in residential living areas or in non-adequately ventilated
enclosed spaces. Never bring or store a propane cylinder indoors.
NOT FOR HOME OR RECREATIONAL VEHICLE USE.
DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND THOROUGHLY UNDERSTAND THESE
SAFETY AND OPERATING INSTRUCTIONS. Failure to comply with the precautions and
instructions provided with this heater can result in death, serious bodily
injury, property loss or damage from the hazards of fire, explosions, burns,
asphyxiation or carbon monoxide poisoning. Only persons who can read and
understand these instructions should use or service this heater.
This is an unvented portable heater. It uses air (oxygen) from the area in
which it is used. Adequate combustion and ventilation air must be provided.
Refer to VENTILATION on Page 9.
WARNING: This product can expose you to chemicals, including lead and lead
compounds, which are known to the State of California to cause cancer and
birth defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov.
WARNING: PERSONS WHO ARE IMPAIRED OR UNDER THE INFLUENCE OF ALCOHOL OR
DRUGS SHOULD NOT OPERATE HEATER.
This heater is designed and approved for use as a construction heater in
accordance with the standard for Gas-Fired Construction Heaters ANS Z83.7 *
CSA 2.14-2017. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY
QUESTIONS ABOUT APPLICATIONS. Other standards govern the use of fuel gasses
and heating products for specific uses. Your local authority can advise you
about these.
RISK OF INDOOR AIR POLLUTION!
The products described in this manual are propane direct-fired, forced air
heaters. Propane forced air heaters are primarily intended for use for
temporary heating of buildings under construction, alteration or repair.
Direct-fired means that all of the combustion products of the heater enter the
heated space. This appliance is rated at 98% combustion efficiency, but does
produce small amounts of carbon monoxide.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
Carbon monoxide is toxic. Humans can tolerate only small amounts of carbon
monoxide and so precautions should be taken to provide proper ventilation.
Failure to provide proper ventilation in accordance with the instructions in
this manual can result in death.
People with breathing problems should consult a physician before using this
heater. Early signs of carbon monoxide poisoning resemble the flu. Symptoms of
improper ventilation / carbon monoxide poisoning are:
Headache · Dizziness · Nausea · Dry Mouth Sore Throat · Burning of Nose and
Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater serviced and check for proper
ventilation. Some people are more affected by carbon monoxide than others.
These include: pregnant women, those with heart or lung problems, anemia or
those under the influence of alcohol or at high altitudes.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY FOR: The temporary heating of adequately ventilated buildings or structures under construction, alteration or repair! Provide at least a three square foot (2,800 sq. cm) opening of outside air for every 100,000 Btu / Hr (29 kW) heater rating. Refer to “Ventilation” on page 8 for further instructions.
PROPANE IS AN EXPLOSIVE GAS.
WHAT TO DO IF THE SMELL OF GAS IS PRESENT:
- DO NOT attempt to light the heater.
- Extinguish any open flame.
- Shut off gas to heater.
- If odor continues, contact your local gas supplier or fire department.
- DO NOT touch or use any electric switch or any electric device that can cause a spark.
- Immediately call your gas supplier from a neighbors phone. Follow the gas suppliers instructions.
- If you can not reach your gas supplier, call the fire department. Service must be done by a qualified service agency.
RISK OF BURNS, FIRE AND EXPLOSION!
NEVER store or use gasoline or other flammable vapors and liquids in the
vicinity of this heater.
NEVER store a propane (LP) cylinder not connected to this heater in the
vicinity of this heater.
NEVER connect heater to an unregulated gas supply.
NEVER obstruct the flow of combustion and ventilation air. (The front and rear
of heater).
NEVER use duct work in front or rear of heater.
NEVER modify this heater or operate a heater that has been modified.
NEVER service, move or handle heater while still hot or operating
Keep all combustible materials away from this heater.
The appliance are be kept clear and free from combustible materials, gasoline
and other flammable vapors and liquid.
Minimum Clearance From Combustibles
Sides | To p | Front | Rear |
---|---|---|---|
24 in. | 36 in. | 72 in. | 24 in. |
61 cm | 92 cm | 183 cm | 61 cm |
ALWAYS use the electrical power (voltage and frequency) specified on the model plate of the heater. ALWAYS use only 14 AWG or better extension cord. ALWAYS unplug the heater when not in use.
CAUTION! HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, ANIMALS,
CLOTHING AND COMBUSTIBLES AWAY FROM HEATER.
AIR QUALITY HAZARD
- Do not use this heater for heating human living quarters
- Use of direct-fired heaters in the construction environment can result in exposure to levels of CO, CO₂, and NO₂ considered to be hazardous to health and potentially life threatening
- Do not use in unventilated areas
- Know the signs of CO and CO₂ poisoning
- Headaches, stinging eyes
- Dizziness, disorientation
- Difficulty breathing, feels of being suffocated
- Proper ventilation air exchange (OSHA 29 CFR 1926.57) to support combustions and maintain acceptable air quality shall be provided in accordance with OSHA 29 CFR Part 1926.154, ANSI A10.10 Safety Requirements for Temporary and Portable Space Heating Devices and Equipment used in the Construction Industry or the Natural Gas and Propane Installation Codes CSA B149.1
- Periodically monitor levels of CO, CO₂ and NO₂ existing at the construction site – at the minimum at the start of the shift and after 4 hours.
- Provide ventilation air exchange, either natural or mechanical, as required to maintain acceptable indoor air quality
- Ensure that the flow of combustion and ventilation air exchanges cannot become obstructed
- As the building “tightens up” during the construction phase ventilation may need to be increased
USA 8-Hr Time weighted average
(OSHA 29 CFR 1926.55 App A)
CO | 50 ppm |
---|---|
CO₂ | 5000 ppm |
NO₂ |
USA – Ceiling Limit
(Short Term Exposure Limit = 15 minutes)
CO|
---|---
CO₂|
NO₂| 5 ppm
Canada 8-hr time weighted average WorkSafe BC OHS Guidelines Part 5.1 and
Ontario Workplaces Reg 833
25 ppm
5000 ppm
3 ppm (Reg 833)
Canada STEL (15 minutes Reg 833/1 hour WSBC) WorkSafe BC OHS Guidelines Part
5.1 and Ontario Workplaces Reg 833
100 ppm
15000 ppm (WSBC)
30000 ppm (Reg 833)
1.0 ppm (WorkSafeBC)
5.0 ppm (Reg 833)
RISK OF ELECTRIC SHOCK!
Electrical Grounding Instructions: This appliance is equipped with a
three-prong (grounding) plug for your protection against shock hazard and
should be plugged directly into a properly grounded three-prong receptacle.
For use with propane (LP) gas only.
ALWAYS install the heater so that it is not directly exposed to water spray, rain, dripping water, or wind.
- Use heater in accordance with all local codes. In the absence of local codes, refer to The National Fuel Code, ANSI A223.1/NFPA 54.
- This heater is shipped from the factory for use with propane (LP) gas only. Do not convert to any other gas. Installation must conform to local codes, or in their absence, with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and the Natural Gas and Propane Installation Code CSA B149.1.
- Gas supply connections should be checked by using a 50/50 soap and water solution. Never use a flame to check for gas leaks.
- Locate LP cylinder at least 6 ft. (183 cm) (10 ft./305 cm in Canada) from the heater, and do not direct heater discharge towards the LP cylinder unless it is at least 20 feet (610 cm) from the heater.
- Use only the regulator and hose assembly provided with this heater. Inspect the regulator/hose assembly prior to each use of the heater. If there is excessive abrasion or wear, or if the hose is cut, replace it with the proper assembly shown in the parts list, prior to using the heater.
- The hose assembly shall be visually inspected prior to each use of the heater. If it is evident there is excessive abrasion or wear, or the hose is cut, it shall be replaced prior to the heater being put into operation. The replacement hose assembly shall be that specified by the manufacturer.
Manifold, Minimum, and Maximum Inlet Pressure
| 60VMHD-GFA| 150VMHD-GFA
---|---|---
Man.| 11″ (279 mm) W.C.| 8″ (203 mm) W.C.
Min.| 5 PSI (34.5 kPa)
Max.| Bottle Pressure
The hose assembly shall be pro tected from traffic, building material and
contact with hot surfaces both during use and while in storage.
RISK OF FIRE! DO NOT POSITION HEATER IN A DOWNWARD ANGLE.
ALWAYS LOCATE HEATER ON A STABLE AND LEVEL SURFACE (SEE FIGURE 1)!
UNPACKING
- Remove all packing items applied to heater for shipment. Keep plastic cover caps attached to inlet connector and hose / regulator assembly for storage.
- Remove all items from carton 3. Check all items for shipping damage. If the heater is damaged, promptly inform dealer where you purchased the heater.
The Propane (LP) gas pressure regulator and hose assembly supplied with the heater must be used without alteration.
SPECIFICATIONS
Model # | 60VMHD-GFA | 150VMHD-GFA |
---|---|---|
BTU | 40 / 50 / 60,000 | 120 / 135 /150,000 |
Fuel Consumption – Lb./hr (kg/hr) | 1.9 / 2.3 / 2.8 | |
(0.9 /1.04 /1.27) | 5.5 / 6.2 / 6.9 |
(2.50 / 2.81 / 3.13)
Maximum Operating Hours| 11.| 18
Required Cylinder – Lb. (kg)| 20 (9)| 100 (45)
Fuel Type| Propane| Propane
Heating Area – Ft.2 (m2)| 1500 (139)| 3800 (353)
Air Flow (CFM)| 300| 400
Max Outlet Temp – °F (°C)| 491 (255)| 622 (328)
Volts: AC/Hz| 120V / 60Hz| 120V / 60Hz
Amps| 0.6 A| 1.02 A
Specifications subject to change without notice.
FEATURES
WHAT’S IN THE BOX
OPERATION
Propane Supply / Information:
Propane (LP)
This heater is not supplied with a propane cylinder. Use only an approved
propane cylinder.
LP Characteristics
- Flammable, explosive under pressure, heavier than air and pools in low areas.
- In its natural state, propane has no odor, but for your safety an odor that smells like rotten eggs has been added.
- Contact of propane (LP) gas with the skin can cause freeze burns.
- Heater is manufactured for use with propane gas only. DO NOT attempt to convert to any other gas. Such modifications are dangerous and will void the warranty.
- When heater is not in use, LP Cylinder must be turned OFF.
- Be sure that the LP Cylinder is located on a level and stable surface.
- DO NOT use this heater in a basement or below ground level. Propane is heavier than air and will always seek the lowest level. If you suspect a leak, shut off the valve at the LP Cylinder immediately.
The Propane (LP) cylinder must also be equipped with the following:
- A collar to protect the gas valve.
- A shut-off valve terminating a LP cylinder valve outlet as specified in the American National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Connections.
- A safety relief valve having direct communications with the vapor space of the LP cylinder.
- The heater must operate on vapor withdrawal from the operating cylinder.
The amount of Propane (LP) used with this heater varies. Both factors are:
- The amount of gas in the cylinder of LP.
- The temperature of the LP tank and its surroundings.
Minimum Number of LP Cylinders
Average Temp
(ºF / ºC)| 60VMHD-GFA
100 lb. (45 kg)
cylinder| 150VMHD-GFA
100 lb. (45 kg)
cylinder
---|---|---
32º / 0º| 1| 2
20º / -7º| 1| 2
10º / -12º| 1| 3
0º / -18º| 1| 3
-10º / -23º| 2| Use Larger Tank
-20º / -29º| 2| Use Larger Tank
The table above shows the minimum number of 100 lb.
(45 kg) LP cylinders required in cold weather. Your local LP dealer will help
you select the proper LP supply system.
Propane is safe to use when properly handled. Careless handling of the LP cylinder could result in a fire and or an explosion.
- Always keep LP cylinder fastened and upright.
- Avoid tipping the LP cylinder on its side when connected to a regulator, since this may cause damage to diaphragm in the regulator.
- Handle valves with care.
- Never connect an unregulated LP cylinder to a construction heater.
- DO NOT subject LP cylinder to excessive heat.
- Tightly close the gas shutoff valve on the LP cylinder after each use.
- All fittings must be protected when disconnected from the LP cylinder.
- Never store an LP cylinder inside a building or in the vicinity of an gas burning appliances.
Installation of this appliance at altitudes above 2000 ft (610 m) shall be in accordance with local codes, or in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or National Standard of Canada, Natural Gas and Propane Installation Code, CSA B149.1.
The disconnected tank must never be stored in a building, garage or any
other enclosed area.
Pre-Lighting Instructions:
Purging and filling of the LP cylinders must be performed by personnel
who have been thoroughly trained in accepted LP gas industry procedures.
Failure to follow these instructions may result in explosion, fire, severe
personal injury or death.
Connecting the LP Cylinder
ALL NEW LP CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING.
-
Turn heater gas valve knob and LP cylinder valve to OFF position.
-
LP cylinder valve equipped with old style fitting has LEFT HANDED THREADS. Turn fitting CLOCKWISE to loosen. Protect this fitting when disconnected from LP cylinder.
-
Have your LP cylinder filled by your local propane gas supplier.
-
Some LP cylinders have a bleed-OFF valve. This valve should be inspected for leaks after each filling of the LP cylinder. Turn the valve clockwise to close.
-
Fasten full propane tank and connect proper fitting to LP cylinder valve by turning COUNTERCLOCKWISE (See Figure 2 & 3).
-
With heater gas valve knob still in OFF position turn ON the LP cylinder valve and check for leaks with soap solution.
Checking For Leaks
- To check for leaks, make up a 50/50 solution of dish soap and water. Apply this solution to all gas connections. If bubbles appear, there is a leak. If a leak is found, turn off the gas supply, and reconnect the leaking connection. If the leak persists after several tries, contact Pinnacle Customer Service at 800-641-6996.
- The installation of this heater must meet all local codes and/or gas utility requirements. In the absence of local codes, the National Fuel Code ANSI Z223.1/NFPA 54 should be followed.
- The minimum clearances to any combustible construction materials must be maintained at all times (See Page 3).
- Inspect the heater before each use, and at least annually by a qualified service person.
Lighting Instructions: Starting the Heater (Ignition)
-
Connect the heater to a three prong (grounded) power source. You must use a three prong (grounded) extension cord that is at least 6 feet long is a minimum of 14 AWG rating.
NOTE: Heater has continuous electronic ignition and will make clicking/sparking noise until heater is lit. -
Connect heater to a proper LP cylinder.
-
Turn gas control knob CLOCKWISE to off position.
-
Wait five (5) minutes for any gas to clear. Smell for gas, if you do not smell gas, go to step 5.
-
Turn gas supply ON by turning the LP cylinder valve COUNTERCLOCKWISE to OPEN.
-
Push in and turn gas control knob COUNTERCLOCKWISE to 1 position. This will light the burner. If needed, keep pressing control knob until the burner lights (See Figure 4).
-
Keep the gas control knob depressed for at least 30 seconds after lighting the burner. After 30 seconds, release the control knob.
-
If the burner doesn’t stay lit, repeat lighting procedures.
-
When burner stays lit, turn gas control knob COUNTERCLOCKWISE to desired setting.
Shutdown Instructions
To Shut Off the Heater:
- Turn gas control knob CLOCKWISE to “O” (OFF) position (See Figure 4).
- Turn gas supply OFF by turning the LP cylinder valve CLOCKWISE to close. (Always turn gas off at the propane supply cylinder(s) when the heater is not in use)
- Disconnect the power cord.
Test Firing the Heater
Test fire your construction heater following the lighting instructions
applicable to the gas control system employed.
Leak test all gas connections with 50/50 soap and water solution prior to
start-up. Soap bubbles indicate a gas leak. DO NOT use a match or flame to
test for gas leaks.
NOTE: Heater surface temperature must be cold before initiating service,
cleaning with recommended cleaning agents if necessary, or storage.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
Not for use in residential living areas or in non-adequately ventilated
enclosed spaces.
VENTILATION
-
Risk of indoor air pollution and Carbon
Monoxide Poisoning. Use heater only in well ventilated areas. -
Refer to Safety Information on pages 2-3 for information about Carbon Monoxide
-
ALWAYS provide a fresh air opening in the heated space of at least three square feet
Minimum Ventilation Opening Needed
60VMHD-GFA | 150VMHD-GFA |
---|---|
1.8 ft.2 | 4.5 ft.2 |
1670 cm2 | 4180 cm2 |
WIRING/SCHEMATIC DIAGRAMS
60VMHD-GFA / 150VMHD-GFA
STORAGE / MAINTENANCE
Always disconnect the heater from the LP cylinder before putting the heater into storage. If for any reason the heater is to be stored indoors, the tank MUST be disconnected from the LP cylinder, and the cylinder stored outdoors in a well-ventilated area, out of the reach of children, and in accordance with the Standard for Storage and Handling of Petroleum Gases, ANSI/NFPA 58 – latest edition and Natural Gas and Propane Installation Code, CSA B149.1. The plastic valve plug or valve cover supplied with the cylinder must be re- installed on the valve to protect the fitting from damage.
NOTE: Installation and repair of this heater should be done by a
qualified service person.
ALWAYS be sure to follow proper maintenance procedures. This should
include cleaning the inside of the heater once a month and checking the spark
gap at least once a heating season. Re-gap the terminals to 0.160″ (4mm)
Never store an LP cylinder inside of a building or near any other gas or oil
burning appliances.
TROUBLESHOOTING GUIDE
Problem | Possible Cause(s) | Solution |
---|---|---|
Fan does not turn when electricity is connected. | 1. No electric power to |
heater.
2. Blades of fan in contact with heater housing.
3. Fan blades bent.
4. Fan motor defective.| 1. Check current at outlet If voltage is correct,
inspect extension and power cords for cuts, frays or breaks
2. Check housing for damage. Be sure there are no dents in the housing
obstructing the fan.
3. Straighten all fan blades.
4. Replace motor assembly.
Heater will not fire (Ignite).| 1. No spark at module.
2. Corroded electrode.| 1. Inspect module wire. Re-attach or tighten if
loose. Inspect spark module and replace if necessary.
Inspect all other electrical components.
2. Replace spark plug (multi-bracket assembly).
Heater stops running by itself.| 1. Temperature inside heater is too high,
causing thermal switch to shut down operation.
2. Damaged control valve.
3. Dust or debris accumulated in heater.| 1. If the heater input or output
is restricted, the inside temperature can become too hot. Keep the areas in
front and behind heater clear of obstructions.
2. Replace control valve.
3. Clean inside of heater.
EXPLODED VIEW
PARTS LIST
Item # | Description | 60VMHD-GFA | 150VMHD-GFA |
---|---|---|---|
1 | Height Controller | 22-512-0006 | 22-512-0008 |
2 | Base Cover | 22-508-0003 | 22-508-0004 |
3 | Inner Shell Cap | 22-505-0010 | 22-505-0008 |
4 | Multi Bracket Assembly | 22-504-0002 | 22-504-0002 |
5 | Tubing Assembly | 22-605-0001 | 22-605-0007 |
6 | Nozzle | 22-081-0014 | 22-081-0004 |
7 | Nozzle Nut | 22-518-0001 | 22-518-0002 |
8 | Handle | 70-001-0103 | 70-001-0103 |
9 | Fan | 22-514-0001 | 22-514-0002 |
10 | Cushion Pad | 22-509-0001 | 22-509-0001 |
11 | Motor | 22-061-0015 | 22-061-0016 |
12 | Rear Guard | 22-101-0003 | 22-101-0004 |
13 | Round Bolt | 22-503-0002 | 22-503-0002 |
14 | Valve Assembly | 22-011-0017 | 22-011-0008 |
15 | Inlet Connector | 22-507-0003 | 22-507-0003 |
16 | Spark Module | 22-604-0005 | 22-604-0005 |
17 | PCB Assembly | 22-521-0002 | 22-521-0002 |
18 | PCB Case | 22-506-0001 | 22-506-0001 |
19 | Valve Knob | 22-516-0001 | 22-516-0001 |
20 | Regulator Assembly | 22-041-0004 | 22-041-0005 |
LIMITED WARRANTY
Pinnacle Climate Technologies, Inc. warrants this product to the original
retail purchaser only, to be free from defects in material and workmanship for
a period of one (1) year from the date of initial pur delivery chase. This
product must be properly installed, maintained and operated in accordance with
the instructions provided.
Pinnacle Climate Technologies, Inc. requires reasonable proof of your
date of delivery from an authorized retailer or distributor. Therefore, you
should keep your sales slip, invoice or cancelled check from the original
purchase. This Limited Warranty shall be limited to the repair or replacement
of parts, which prove defective under normal use and service within the
warranty period, and which
Pinnacle Climate Technologies, Inc. shall determine at its reasonable
discretion.
This Limited Warranty does not cover any failures or operating difficulties
due to normal wear and tear, accident, abuse, misuse, alteration,
misapplication, improper installation or improper maintenance and service by
you or any third party. Failure to perform normal and routine maintenance on
the product, shipping damage, damage related to insects, birds or animals of
any kind, and damage due to weather conditions are also not covered. In
addition, the Limited Warranty does not cover damage to the finish, such as
scratches, dents, discoloration, rust or other weather damage, after purchase.
All transportation costs for the return of damaged product or parts will be
the responsibility of the purchaser. Upon receipt of the damaged item,
Pinnacle Climate Technologies, Inc. will examine the item and determine if
defective. Pinnacle Climate Technologies, Inc. will repair or replace and
return the item, freight pre-paid.
If Pinnacle Climate Technologies, Inc. finds the item to be in normal
operating condition, or not defective the item will be returned freight
collect. This Limited Warranty is in lieu of all other express warranties.
Pinnacle Climate Technologies, Inc. disclaims all warranties for products that
are purchased from sellers other than authorized dealers or distributors.
AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS WARRANTY EXPIRES, Pinnacle
Climate Technologies, Inc. DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING
WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR APPLICATION. FURTHER, Pinnacle Climate Technologies, Inc. SHALL
HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL,
INDIRECT, PUNITIVE INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Pinnacle Climate
Technologies, Inc. assumes no responsibility for any defects caused by third
parties. This Limited Warranty gives the purchaser specific legal rights; a
purchaser may have other rights depending upon where he or she lives. Some
states do not allow the exclusion or limitation of special, incidental or
consequential damages, or limitations on how long a warranty lasts, so the
above exclusion and limitations may not apply to you.
Pinnacle Climate Technologies, Inc. does not authorize any person or
company to assume for it any other obligation or liability in connection with
the sale, installation, use, removal, return or replacement of its equipment,
and no such representations are binding on Pinnacle Climate Technologies, Inc.
Always be sure to specify the model number and serial number when making any
claim with Pinnacle Climate Technologies, Inc. For your convenience, use the
space provided below to list this information.
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of
your heater. It will begin with the letter “G” followed by 9 digits. For
Example: G123456789. Have your Serial Number ready before calling customer
service at 800-641-6996.
Model #:____
Serial #:____
Date of Purchase: _____
© 2023 Pinnacle Climate Technologies, Inc.
Propane Forced Air Heater User’s Manual