Product Information

Specifications

  • Product Size: 132mm x 36.9mm x 14.6mm
  • Motor Model: YR5302
  • Emission Frequency: BLE 5.0
  • Communication Protocol: 4
  • Use Battery: AAA Battery x 2pcs
  • Transmission Channel: Two channels modes
  • LED Indicator Function: Yes

Button Functions

  • [Up/Open]: Open the curtain.
  • [Down/Close]: Close the curtain.
  • [Intermediate Stop 75%]: Short press to up tilting.
  • [Intermediate Stop 50%]: Short press, stop. If long press for 1.5 seconds, it runs to the IP1 limit position. If pressed for 4 seconds, it runs to the default 50% limit. The default is 75%.
  • [Stop/50%]: Used in combination with other buttons for various functions.
  • [Channel Selection]: Used to select the channel.
  • [Channel Setting]: Used for channel setting and entering different modes.

Product Usage Instructions

Channel Selection and Switching Modes

To switch between two channels mode and four channels mode:

  1. Press the [Channel Selection] button when the remote control LED is off.
  2. The indicator light of the current channel will light up.
  3. Press the [Channel Selection] button again within 3 seconds to select the channel.
    • In two channels mode, the sequence is Channel 1 and Channel 2
    •  group control channel.
    • In the channels mode, the sequence is Channel 1, Channel 2, Channel 3, and Channel 4 group control channel.

Combination Button Functions

Various functions can be achieved by combining specific buttons:

  • [Channel Selection]+[Stop/50%]: Used for reversing. Press [Channel Selection]+[Stop/50%], then long press for 5 seconds to start the controller or motor entering the code. After that, press the [Channel Setting] button to confirm the learning state and receive the matched reversing to confirm.
  • [Stop/50%]+[Up/Open]: Long press for 5 seconds to enter the ready-to-disable manual start state. Then, short press the [Channel Setting] button to confirm and make the motor enter the state of setting on the limit point.
  • [Stop/50%]+[Down/Close]: Long press for 5 seconds to make the motor enter the limit point state of the down setting.
  • [Channel Setting]+[Up/Open]: Press long for 5 seconds to enter the learning state and receive the paired mode switching function code after entering the code learning state.
  • [Channel Setting]+[Down/Close]: Press for 5 seconds at the same time to make the motor enter the limit point state of the down setting.
  • [Up/Open]+[Down/Close]: Used for external control mode switching. The controller or motor will only process the limit point state of the down setting after receiving the paired mode switching function code after entering the code learning state.
  • [Channel Setting]+[75%]: Short press at the same time to set the IP1 limit position.
  • [Channel Setting]+[25%]: Short press at the same time to set the IP2 limit position.
  • [Channel Setting]+[Stop/50%]: Long press at the same time to clear the limit position.

FAQ

  • How do I switch between two channels mode and four channels mode?
  • To switch between two channels mode and four channels mode, follow these steps:
    •   * Press the [Channel Selection] button when the remote control LED is off.
    • The indicator light of the current channel will light up.
    • Press the [Channel Selection] button again within 3 seconds to select the channel.
    • In two channels mode, the sequence is Channel 1 and Channel 2 group control channel.
    • In the channels mode, the sequence is Channel 1, Channel 2, Channel 3, and Channel 4 group control channel.
  • What are the button functions of the remote control?
  • The buttons on the remote control have the following functions:
  1. * [Up/Open]: Open the curtain.
    • [Down/Close]: Close the curtain.
    • [Intermediate Stop 75%]: Short press to up tilting.
    • [Intermediate Stop 50%]: Short press, stop. If long press for 1.5 seconds, it runs to the IP1 limit position. If pressed for 4 seconds, it runs to the default 50% limit. The default is 75%.
    • [Stop/50%]: Used in combination with other buttons for various functions.
    • [Channel Selection]: Used to select the channel.
    • [Channel Setting]: Used for channel setting and entering different modes.

Information

Product size

Note: The length L of the remote control depends on product specifications (unit: mm)

Button function

  1. p/Open
  2. Intermediate stop 75%
  3. Down/Close
  4. Intermediate stop 25%
  5. Stop/50%
  6. Channel selection
  7. Channel

Product Specifications

Motor model YR5302
Emission frequency 7±1dBm
Use battery AAA BATTERY X 2pcs

LED indicator function

  • Two channels modesMAXPAY-PAZARLAMA-R5302-Hand-Held-Remote-Control-fig-3
  • Four channels modesMAXPAY-PAZARLAMA-R5302-Hand-Held-Remote-Control-fig-4

Channel setting

  • The way to switch two channels and four-channel modes
    The current maximum number of channels in use is set to two or four-channel switch.

  • Two-channel modeMAXPAY-PAZARLAMA-R5302-Hand-Held-Remote-Control-fig-6
    Press the [Channel Selection] when the remote control LED is off, and the indicator light of the current channel will light up. Press the [Channel Selection] again within 3 seconds, and select the channel in the sequence of channel 1→ Channel 2→ group control channel → Channel 1.

  • Four-channel modeMAXPAY-PAZARLAMA-R5302-Hand-Held-Remote-Control-fig-7
    Press the [Channel Selection] when the LED of the remote control is off, and the indicator light of the current channel will light up. Press the [Channel Selection] again within 3 seconds, and select the channel in the sequence of channel 1→ Channel 2→ Channel 3 Channel 4→ group control channel

Button function

  • Single button function

MAXPAY-PAZARLAMA-R5302-Hand-Held-Remote-Control-fig-8

  • Combination button function

MAXPAY-PAZARLAMA-R5302-Hand-Held-Remote-Control-fig-9

FCC

FCC Caution:

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2.  this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals