POWERASIA B0BLGYMXXT LED Retrofit Modules Instruction Manual
- June 14, 2024
- POWERASIA
Table of Contents
LED Retrofit Modules
Description
The LED retrofit module is designed to replace traditional halogen bulbs and fluorescent bulbs mounted in the lamp, anti-glare design, 1200 lumens, 90+ CRI, dimming with many ELV dimmers. Suitable for damp locations with night light, night light mode emits 2000K amber for very soft illumination and added ambiance.
Specifications
Aluminum construction diffused polycarbonate lens Intuitive snap-in mounting system Fits most 5″/6″ housing Suitable for damp 1ocations Triac dimmable, Dimmable to 5% brightness Anti-glare design with night light.
Performance
Number of modules | 1 |
---|---|
Input power | 12W+3W |
Input voltage | 120V |
Input frequency | 60HZ |
Lumens/LPw | 100LM/W |
5CCT | 2700/3000/4000/5000/6000K |
Night Light | 2000K |
CRI | 90+CRI |
Life (hours) | 50000h |
FCC | FCC Tit1e 47 |
Min. start temp | -30 ℃ |
Max. operating temp | 30 ℃ |
Warranty | 5 year warranty |
Labels | cETLus, damp location listed |
Housing mount 1:
Installation steps:
- Open the box and take out all the parts on the plane.
- Adjust the part <5> to the corresponding position, the<position is wide,and the 5″ position is narrow> .
- Toggle the part <8> to select the color temperature
- Lock part <6>into part <7>and press part <5>.
- Lock part <3> into part <1>.
- Connect parts <4together.
- Press the part <5> into the part <2>.
- Push the luminaire <7> up hard and let the luminaire <7>fit the ceiling for installation.
- Continuously switch the wall switch within 10 seconds tocontrol the opening and turnover of the main light and night lights.
Housing mount 1:
Installation steps:
- Open the box and take out all the parts on the plane.
- Adjust the part <4>to the corresponding position, the<6 position is wide and the 5″position is narrow>
- Toggle the part <7> to select the color temperature.
- Lock part <5> into part <6> and press part <4>.
- Lock part <2>to part <1>.
- Connect parts <3> together.
- Push the luminaire <6> to the component <1> and push itupso that the 1uminaire <6>fits the ceiling for installation.
- Continuously switch the wall switch within 10 seconds tocontrol the opening and turnover of the main light and night lights.