hotshock AN490 Electric Fence Instruction Manual
- June 13, 2024
- hotshock
Table of Contents
- Operating manual of the hotshock AN490
- General Safety Instructions
- Description and Construction of the Product
- Installation
- Commissioning
- Energizer Operating Description
- Maintenance
- Disassembly, Dismantling, Storage and Transport
- Faults and Repairs
- Spare parts
- max. fence line length
- Installation and connection
- Technical data
- Total Weight
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
hotshock AN490 Electric Fence
Operating manual of the hotshock AN490
In association with the installation and safety instructions for the SECURA ANIMAL or SECURA SECURITY electric fencers (www.horizont.com/securaanimal or www.horizont.com/securasecurity)
General Safety Instructions
Switch off the pasture fencer before coming into contact with it!
Operating manual information
The operating manual has some important instructions on handling the
energizer. All technical details in the manual have been prepared and compiled
with the greatest possible care. Even so, errors cannot be excluded. We wish
to point out that we cannot assume any guarantee, legal responsibility or any
liability for consequences attributable to possible lack of details. We would,
at all times, welcome any notification of possible errors. Safe working
depends on the indicated safety and handling instructions being adhered to.
Also to be adhered to are those local accident prevention provisions which are
in force where the energizer is used as well as the general safety
requirements. The operating manual is to be studied carefully before any work
begins! As an integral part of the overall product it is to be securely kept
right next to the energizer and for ease of consultation by the personnel.
Do hand over this manual should this product be sold or passed on to another
party. For a better understanding of what is involved, some of the diagrams in
this manual may not be true-to-scale and may deviate slightly from the actual
constructional design.
Description and Construction of the Product
The energizer transmits voltage pulses to a connected pasture fence. Switching the energizer on and off (and changing between various operating modes) is undertaken by a push switch (1).
Caution! Only the optional additional parts prescribed by the manu- facturer are to be used.
Installation
Installation:
The energizer can either be mounted on a wall or on a stable post. The earthing rod (longitudinal rod) must be driven as deeply as possible into the ground at a moist location and connected by a corrosion-resistant wire to the earthing terminal ( ) of the energizer. Connect the fence cable to the terminal with the lightning symbols ( or ) ( ) .
The energizer is only protected against moisture if it is properly installed. Shield the energizer from direct solar irradiation. Do not operate the energizer when it lies on the ground. Set the energizer up in a location where there is no fire hazard.
The energizer has two fence outputs: ( ) = maximum; ( ) = reduced. Both outputs can simultaneously operate separate fences. A short-circuit at the reduced fence output will hardly affect the maximum out- put, but a defect at the maximum output will additionally lower the reduced output. Only the maximum fence output is shown on the display (LED 4-9) given the connection of two fences.
Earthing:
Good earthing of the fence is extremely important for trouble-free operation
and optimum performance of the energizer; therefore it should be earthed at a
preferably moist and overgrown location.
If the ground is dry and the fence is long, an additional earth conductor with
intermediate earths (every 50 m) should be installed along the fence.
Installation with a 12V rechargeable battery:
Connect the 12V rechargeable battery (red + / black -), ensure clean pole
terminals and correct polarity. The device will not start if the polarity is
reversed.
CAUTION!
Only use rechargeable 12 V batteries; only charge rechargeable batteries with
ventilation in well-ventilated rooms. Disconnect the rechargeable battery from
the energizer during the charging process. The rechargeable battery should be
recharged before and after every use as well as during longer periods of
storage (every 2 months) and disconnected from the energizer.
Installation with a 230V/110V mains adapter:
For the operation of 230V power supply only use the mains adapter 47PSU0010EU
/UK /US, as specified on the intermediate plate in the device!
Installation with 230V/110V:
Insert the energizer’s mains plug into the power socket.
Commissioning
Switch on energizer with the push button (1). After 1 second, you will hear a rhythmic even ticking of the pulses; the energizer is in operation. The energizer transmits pulses to the fence and the LED display lights up. The fact of the status LEDs not lighting up points to a defect in the power supply.
Checking the earthing:
Provoke a short-circuit by driving a metal rod into the ground against the
pasture fence wire (not plastic) about 50 m away from the pasture fencer. The
pasture fencer should now result in the lighting up of only a maximum 1 LED
(moist ground) or of a maximum 2 LEDs (dry ground) (Fig. 5 LED 9 and 8). If
this is not the case, then raise the number and / or length of the earth- ing
posts.
Energizer Operating Description
Rechargeable battery indicator:
The rechargeable battery indicator provides information about the rechargeable
battery or battery voltage. The solar display lights up constantly in green
when the solar panel charging voltage is greater than the voltage of the
rechargeable battery/ battery. Whilst the solar panel charges the 12V
rechargeable battery, it does not charge the 9 volt battery.
Fence voltage indicator
The 6 LEDs (LED4 – LED9) indicate the fence output voltage in 1000V steps. The
indicator builds up from the left. For herding security purposes at least 3
LEDs (3000V) should light up otherwise the voltage is too low.
Possible causes:
- With fence: Marked growth at fence, poor insulators, short-circuit at metal posts, or fence too long
- Without fence: Device is defective, see Service
Power economiser:
A fitted power economiser matches power consumption to the state of the fence.
This means less current consumption with well insulated fences and a greater
current consumption with poorly insulated fences (leakages due to plant
growth, etc.).
Argutector display:
The 6 LEDs ( LEDs 4 to 9) indicate fence insulation by way of the Argutector
display in 6 steps. The display builds up from the right. If all 6 LEDs light
up, the fence insulation is good and little energy is required to maintain
herding security. The fewer the number of lit up LEDs, the poorer the fence
insulation is due to leakages (plant growth, branches fallen onto the fence
system, short-circuit, poor earthing). Increased energy is required to keep
the fence herding-secure.
Argutector display Ranger B:
Pressing the button activates the Argutector test.
If LED (1) does not light up red, then fence insulation is good and little
energy is required to maintain herding security. If LED (1) lights up red,
then fence insulation is poor due to leakage (plant growth, branches fallen
onto the fence system, short-circuit, poor earthing). Increased energy is
required to keep the fence herding-secure.
Maintenance
Table 13 (12V rechargeable battery)
Remaining capacity
| Flashing light| green| | Rechargeable battery good
---|---|---|---|---
| Flashing light| red/
green| | Charge the battery
| Flashing light| red| | Rechargeable battery absolutely depleted
The rechargeable battery must be recharged at the latest when discharged down to 80% (only 20% remaining left) to prevent a flat battery. The rechargeable battery indicator (LED2) lights up:
Do note that temperature and measurement deviation may cause these figures to vary.
Caution!
When using a solar system Only carry out a battery or rechargeable battery
test at start of the day ( no solar power supplied – cover panel )
Disassembly, Dismantling, Storage and Transport
Disassembly, Dismantling
Before starting disassembly:
- Switch off energizer
- Disconnect entire energy supply from the energizer.
- Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmentally compatible manner.
Then properly clean sub-assemblies and parts and disassemble them in taking account of the local industrial safety & environmental protection provisions in force.
Storage, Transport
Ensure that the energizer is both stored and transported only when switched
off
NOTE!
Ensure that rechargeable batteries are stored in ventilated and dry rooms.
Faults and Repairs
WARNING!
Repairs may only be carried out by qualified persons. Only the spare parts
prescribed by the manufacturer may be used.
Subject to technical alterations!
Cycle sequence monitoring
The energizer has a cycle sequence monitoring unit to stop any undue energy
being supplied to the fence, cycle pulses failing and to ensure that herding
security is maintained. The effect of the cycle sequence rate falling to under
1 second or for no pulses to occur for more than 5 seconds is for LED3 to
flash in red. This could be due to lightning strikes, continuous flashovers at
the fence and a defective energizer. The cycle sequence monitoring unit
operates to attain a preferably high degree of security – and fully
independently of pulse generation. For this reason the display may be
incorrect under certain operating modes. Send the energizer in for repair if
the cycle sequence monitoring indicates a fault either following an energizer
restart or in the “Normal“ operating mode.
The CONTROL LED (LED1) lights up green when the energizer is working trouble- free. If the LED lights red, there is a fault.
Table 14
Faults | Display | Corrective action |
---|---|---|
Rechargeable battery under 40% capacity | LED flashes alternately red/green |
Charge the battery
Rechargeable battery under 20% capacity| LED flashes red| Charge the battery
Herding voltage too low| Not all LEDs of the fence voltage indicator light up
green| Set the Normal mode
Plant growth, short-circuiting at the fence| Not all LEDs of the Argutector
display light up green| Free fence from leakages (plant growth, short-
circuits, etc.)
Spare parts
Fig. 1
max. fence line length
Fig. 2
-
hotshock AN490 = 14 x 50m
-
hotshock AN490 = 45 km
Subject to technical alterations!
Installation and connection
Fig. 3
For 230V operation the energizer should be and the adapter must be installed in a room protected from moisture.
Technical data
hotshock AN490, Type 10813
Joule max: 4,9 J / 500 Ω
Fig. 4
| | Joule
IN| Joule
OUT max.| Joule
OUT reduced| max.
Spannung| max.
Spannung| Spannung
500 Ω
---|---|---|---|---|---|---|---
| | |
|
|
|
|
hotshock
AN490| 5 x 1,5m| 5,9 J| 4,9 J| 1,0 J| ~ 19.000 V| 110 – 435 mA| ~ 6.000 V
Total Weight
1,84 kg
Website
Discover our website and find more products, highlights, campaigns, movies, tips and more. We look forward to your visit! http://www.horizont.com/
Advisor electric fencing
By means of our electric fence advisor you can receive useful information about how to arrange a reliable electric fence system. http://www.horizont.com/ACratgeberWeidezaun
Electric fencing catalogue
horizont offers a comprehensive range of electric fencing material. Please don’t hesitate to ask for a catalogue or have a look at our website to download it. http://www.horizont.com/ACkataloge
All data is made subject to sentences mistakes and literal mistakes, subject to product changes and falsity. Reprint, even in extracts and use of the pictures only with written permission by horizont group gmbh.
Customer Support
horizont group gmbh
Animal Care
Homberger Weg 4-6
34497 KORBACH GERMANY
+49 (0) 56 31 / 5 65 – 1 00
+49 (0) 56 31 / 5 65 – 1 20
agrar@horizont.com
horizont.com
References
- Willkommen bei der horizont Gruppe | horizont.com
- Willkommen bei der horizont Gruppe | horizont.com
- Willkommen bei der horizont Gruppe | horizont.com
- Willkommen bei der horizont Gruppe | horizont.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>