ablaze S500C Premium Range Back Lit Mirror Installation Guide
- June 9, 2024
- ablaze
Table of Contents
S500C Premium Range Back Lit Mirror
Installation Guide
S500C / S759C / S900C / S1200C / S1500C / SR759C / SR1118C / RB610W /
RB610C
SS759C / SS128C / RS600C / RS600W / RS900C / RS900W / SO500C / SO500W /
SSC128C
S500C Premium Range Back Lit Mirror
Ablaze Back-Lit Mirrors
Premium Range Back-Lit Mirrors
Installation Guide
Installation
Key
1. Wall & mains supply
2. Junction box
3. Connection block
4. Transformer
5. Demister connection| 6. Heating element
7. Backbox
8. Screw & wall plug
9. Metal hanger
10. Mirror
---|---
The Ablaze Premium Back-Lit Mirror models in this guide are designed to be concealed wired (hardwired) through the back of the mirror and wired into a separate switch, timer or PIR movement sensor. The Ablaze Premium Back-Lit Mirrors come in two parts: the mirror with hangers and demister attached and the backbox containing the lights and transformer. There is a small screw used to secure these two parts together during transportation which needs to be removed prior to installation.
-
Switch off the main power
You will be installing the Ablaze Back-Lit Mirror as part of a high voltage mains electrical circuit. To ensure your safety and to protect the mirror, switch off the mains power before you start the installation. -
Plan the installation and layout
The Ablaze Back-Lit Mirrors require mains supply and a switch/timer/PIR movement sensor. Measure out and install all the necessary items before you install the mirror. -
Fix the backbox to the wall and connect to main supply
Remove the small fixing screw that holds the backbox to the mirror (see diagram below) and lift the backbox away from the mirror. Place the backbox onto the wall central to your desired final position. Whilst in position mark the four fixing holes. Drill pilot holes in the four marked position and insert wall plugs. Screw the backbox into position. Pull the mains supply cable through the centre of the backbox and wire into the connection block.Please note the location of the screw will differ for each model -
Hang the mirror onto the backbox
Connect the Thermometer demister by slotting the black cable from the back of the mirror into the black cable at the connection block. Line up the mirror above the backbox and gently lower the mirror until the brackets clip into place and you can feel the backbox take the weight of the mirror.
Technical Specifications
CODE| LIGHT| SIZE (MM)| MOUNTING| OUTPUT WATTAGE|
DEMISTER INCLUDED
---|---|---|---|---|---
S500C| Cool| W750 x H500 x D45| H / V| 39| Y
S759C| Cool| W900 x H750 x D45| H / V| 55| Y
S900C| Cool| W900 x H900 x D45| N/A| 68| Y
S1200C| Cool| W1200 x H800 x D45| H / V| 103| Y
S1500C| Cool| W1500 x H800 x D45| H / V| 115| Y
SR759C| Cool| W900 x H750 x D45| H / V| 55| Y
SR1118C| Cool| W1200 x H800 x D45| H / V| 66| Y
RB610W| Warm| 610 ø x D45| N / A| 18| N
RB610C| Cool| 610 ø x D45| N / A| 18| N
SS759C| Cool| W900 x H750 x D45| H / V| 86| Y
SS128C| Cool| W1200 x H800 x D45| H / V| 108| Y
RS600C| Cool| 600 ø x D43| N / A| 41| Y
RS600W| Warm| 600 ø x D43| N / A| 41| Y
RS900C| Cool| 900 ø x D43| N / A| 79| Y
RS900W| Warm| 900 ø x D43| N / A| 79| Y
SO500C| Cool| W500 x H1000 x D45| V| 39| Y
SO500W| Warm| W500 x H1000 x D45| V| 39| Y
SSC128C| Cool| W1200 x H800 x D45| H| 39| Y
H = Horizontal Mount
V = Vertical Mount
Supply Voltage | 240V 50Hz |
---|---|
Wiring Method | Hardwired |
Warranty | 3 Years |
Lightning Type | LED |
Safety & Care Information
Safety Information
Ablaze Back-lit Mirrors should be installed and tested by a qualified
electrician and in accordance with current local regulations. Where possible
the Ablaze Back-Lit Mirror should be screwed into studs or other suitable dry
wall anchors, if fixing to hollow walls suitable anchors should be used.
Please read and understand this installation guide in before commencing
installation.
If you have any queries in regards to installation, please call 1300 368 631.
- Observe and adhere to electrical guidelines when placing your Ablaze Back-Lit Mirror in wet areas
- Ensure any timers or switches used are installed in correct zones according to the IP rating of the timer/switch.
Care Information
For best results clean mirrors with methylated spirits and water at a rate of
30% methylated spirits and 70% water. Do not use Windex or similar chemical
cleaning products. Avoid getting water on the sides or back of the mirror as
damage to the silver backing can occur. In coastal areas it is recommended to
wipe around the edge of the mirror once a month to avoid salt build up that
can cause silver creep.
Warranty Registration
Thermograph covers all its products with a satisfaction guarantee. In addition, Thermograph will supply a replacement product where a fault is shown to be caused by manufacture, materials or workmanship providing the goods have been installed correctly and according to installation instructions. This guarantee does not include removal, freight or installation costs. Thermograph’s products come with guarantees that cannot be excluded under Australian Consumer Law and you are entitled to a replacement or refund for a major failure & compensation for any other reasonable foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
To use the warranty, repair or service the customer must provide purchase
invoice/receipt, and completed warranty registration form.
If the product develops a fault within the warranty period due to normal wear
and tear,
Thermograph at its discretion will recognise whether it’s a faulty product or
not. If it is impossible or not economical for the manufacturer to repair the
product, the manufacturer will replace the faulty product with a new unit of
the same model or if there is no stock available of the same model as the
product, the manufacturer will replace the product with a new unit of a
similar size. No responsibility can be taken for altered dimensions and lining
up of existing holes.
The repair service offered within the warranty period only covers the faults
and problems as developed from the manufacturer’s errors. Any damage caused by
improper use or carelessness or incorrect wiring is not covered.
Thermograph is not responsible for any monetary loss or injuries caused by
improper use of this product.
Contact Us
Contact Us
Thermograph sales@thermogroup.com.au
Phone: 1300 368 632 Technical Helpline: 1300 989 464
www.thermogroup.com.au