PAN ACOUSTICS PB 04 Pan Beam series with Beam Steering Instruction Manual
- June 10, 2024
- PAN ACOUSTICS
Table of Contents
PB 04 Pan Beam series with Beam Steering
Instruction Manual B 04 Pan Beam series with Beam Steering Instruction
Manual
DOCUMENTATION
PAN BEAM SERIES OPERATING AND INSTALLATION MANUAL
PB 04, PB 08, PB 16, PB 24, PB 32, PB 40, PB 224, PB 248, PB 272, PB 296
V 1.1
PAN BEAM ACTIVE DSP COLUMN SPEAKER PURE ACOUSTICS
Shapely.
Versatile.
Functional.
Read the operating manual carefully prior to putting the device into
operation.
The operating manual is to be kept in a safe place.
www.pan-acoustics.de
Pan Acoustics GmbH │ Lindener Str. 15
D-38300 Wolfenbüttel │ Germany
Tel.: +49 (0) 5331 900 95 70
Email: kontakt@pan-acoustics.de
Introduction
Thank you for choosing a product from Pan Acoustics. The active column
speakers with DSP technology from the Pan Beam® series combine an appealing
architectural design with modern beam steering technology.
The Pan Beam series offers a comprehensive speaker portfolio, e.g. for
acoustically diffi cult environments, traditional AV installations, theater
and outdoor applications. The portfolio is made complete by properly-matched
subwoofer systems. All products of the Pan Beam series are optimized for
natural speech and music reproduction.
Please read this operating manual carefully prior to startup in order to
guarantee fault-free operation.
1.1. Symbols and explanation
DANGER This symbol indicates a hazard with a high level of risk. If this
hazard is not prevented, severe injuries or death may result.
WARNING This symbol indicates a hazard with a moderate level of risk. If
this hazard is not prevented, moderate to severe injuries or death may result.
CAUTION This symbol indicates a hazard with a moderate level of risk.
Failure to observe this instruction may lead to minor injuries or property
damage.
NOTICE This symbol provides important instructions for proper handling of
the product. Failure to observe this instruction may lead to damage to the
product or malfunctions.
1.2. General information and target group
All specifi cations in this operating manual are based on the product features
available at the time of production and the safety rules applicable at that
time.
This operating manual describes the confi guration, function and connection of
the Pan Beam speaker systems PB 04, PB 08, PB 16, PB 24, PB 32, PB 40, PB 224,
PB 248, P 272, PB 296 to the power supply and audio sources. It is geared
towards systems technicians and persons assigned the task of installing and
operating a relevant system.
Pan Acoustics reserves the right to make changes and modifi cations without
prior notice within the scope of statutory regulations and product
improvements.
This operating manual and all additional information required for operation
(see also: “Pan Beam setup” in the operating manual in its current version)
must be read prior to
use by all persons involved in commissioning. The operating manual and all
additional information required must be kept within reach, near the device.
All necessary information and documents can be obtained from the Pan Acoustics
website, www.pan-acoustics.de/de/manuals.html, or per email from kontakt@pan-
acoustics.de.
NOTICE The Pan Beam series speaker systems can only be confi gured and
maintained (fi rmware update) using the Pan Beam Setup confi guration
software. An appropriate interface such as Pan Con, Pan Splitter, Pan
Powerline CCU or the installation of the Dante controller from the manufacture
Audinate Ltd. is required to connect the speakers to a PC.
1.3. General safety regulations
The following safety regulations are to be read completely and diligently
prior to commissioning the device and afterwards kept in a safe place near the
device. Reading the instruction manual is no substitute for knowing and
following all valid local safety regulations and rules. The information and
technical specifications published in this document are based on data
available at the time of publication. We reserve the right to make changes to
the product aimed towards product improvement and adjustment to new applicable
standards.
DANGER
The device conforms to Protection Class 1. For safety reasons, the device may
only be operated on a properly-installed outlet with a grounded socket. The
grounded socket connection is never allowed to be dismantled. The rated
voltages for the device must be consistent with the line voltage of the power
supply. In order to prevent injuries, electric shock and fi re, ensure that
all persons involved in the set up, operation, dismantling or installation of
the device/system have read this operating manual.
WARNING
In order to prevent electrical shock,
- the product is not allowed to be connected to the power supply if the enclosure is open.
- the product is only allowed to be used with an intact power cord.
- the product is only allowed to be connected to a power supply if the line voltage is consistent with the voltage indicated on the device.
- the product is only allowed to be assembled and mounted when disconnected from the power supply.
- pull only the plug, never the wire, when unplugging the device.
- objects are not allowed to be placed on top of the power cord of the device.
- the electrical cables are to be installed so that they are protected from damage due to foot traffic, pinching and tensile load.
- ensure that all devices interconnected via signal wires are operated with CEE sockets on a common protective ground.
In order to reduce the risk of fi re or electrical shock,
-
the product is not allowed to be exposed to moisture or humidity.
(Exception: versions with an appropriate IP protection class). -
no objects (e.g. bottles) fi lled with liquid are allowed to be placed on top of the device.
-
ventilation slots are not allowed to be covered up with objects (e.g. textiles).
-
the device is not allowed to be subjected to excessive heat, direct sunlight, fire or similar influences.
-
no open sources of fi re (e.g. candles) are allowed to be placed on top of the device.
In order to prevent injury, it is necessary to decommission this product, clearly mark it and secure it from being inadvertently put back into operation if the product
- shows signs of visible damage.
- contains loose parts.
- no longer runs fault-free.
- was in prolonged storage under adverse conditions (e.g. in humid rooms).
- was subjected to severe transport stress (e.g. with improper packaging).
To avoid damage to the device and injuries to personnel,
- this product should be kept out of the reach of children.
To avoid injuries such as hearing damage from excessive volume levels, persons should
- never stand directly in front of a connected speaker.
- not be subjected to high volume levels for a prolonged period.
CAUTION
In order to prevent damage to the product, avoid
- generating acoustic feedback.
- playing back distorted signals at high power for a prolonged period.
- generating impulse-like sounds (e.g. popping noises), which occur if a media player is switched on, connected or disconnected.
- connecting the product to the power supply for a prolonged period without using it.
- operating the device in environments with high air humidity.
- operating the device without suffi cient possibility of air circulation.
NOTICE
Device protection and operating safety
- The device is completely disconnected from the power supply by pulling the power plug.
- The device is only to be cleaned from the outside using a dry cloth.
- The original packaging should be used when transporting the device. The device is to be protected against vibrations.
1.4. Safety instructions
All products from Pan Acoustics are developed and manufactured in Germany
according to the latest safety regulations. Each product is thoroughly
inspected prior to shipping according to in-house quality guidelines.
The device conforms to the current CE regulations for operation in
residential, business, commercial and industrial areas.
The device is to be carefully inspected upon receipt for shipping damage and
completeness. In case of damage, the forwarder and sender are to be notifi ed
without delay.
Safety may be impaired if the product:
- shows signs of visible damage.
- no longer works properly.
- has been stored under adverse conditions for a prolonged period.
- has been improperly shipped (e.g. unsuitable packaging).
If the product shows signs of impairments that no longer guarantee safe
operation, the device is to be secured and labeled accordingly. It should also
be ensured that no intentional or inadvertent operation by third parties is
possible.
1.5. Setup location
The speaker must be operated in dry places guaranteeing suffi cient air
circulation. Exceptions to this are speakers with an appropriate protection
class, e.g., IP 54 or IP 65.
The device can be damaged due to condensation. That is why devices should be
properly acclimated prior to operation.
The ambient temperature when operating the device should not exceed 40°C and
should not fall below 0°C. Exceptions to this are speakers with an appropriate
modification, see type plate.
WARNING
When unpacking, it is important to pay attention to the temperature difference
between the ambient temperature and the device. In case there is a high
temperature difference, it is necessary to wait for a sufficient period before
commissioning the device in order to prevent damage due to condensation.
NOTICE
If the ambient temperature is higher than 40°C, adequate measures are to be
undertaken to protect the device against overheating. If the speaker
overheats, it automatically shuts off and only on turns on again after cooling
off.
1.6. Scope of delivery
The scope of delivery may vary depending upon the model and can be obtained in
the appendix.
–> See chapter 9.1. “Delivery scope for speakers”
1.7. Definition
Pan Beam
Product series of active speakers, line array with beam steering technology.
Pan Beam Net
Audio and control signals are transmitted via the Pan Beam Net by means of a
(twisted-pair) network cable. The cable must be category CAT 5e or higher. The
cabling is confi gured in a daisy chain.
Pan Beam Setup software
Software for the setup of Pan Beam speakers
Pan Powerline
Transmission technology for audio, control data and power supply over a 2
-wire-system
Beam steering technology
Electronic vertical and horizontal beam steering of an active speaker
Multi beam steering technology
Generation of several so-called sound beams using beam steering technology
Side lobes
Side lobes describe sound artifacts created alongside the main beam direction.
RJ45
Plug connector for transmitting signals
IEC-60320 C13
Internationally standardized power connector for devices (low heat device
socket)
DANTE
Digital audio network protocol for transmission of audio and control data
developed by Audinate.
AES/EBU
Interface for transmission of digital audio signals between various devices
according to AES3
USB
Serial port for connecting devices to a computer
Daisy chain cabling
In this type of cabling, devices are connected serially, i.e. in a circuit
General Purpose Interface (GPI)
A platform-independent circuit connection between devices from different
manufacturers
Product description
2.1. Pan Beam
The Pan Beam models PB 04/08/16/24/32/40/224/248/272/296 are active, digitally
steerable column speakers. The Pan Beam models PB S-208/-118 are active
subwoofer systems. Via the Pan Beam Setup software, the radiating
characteristics of the column speakers can be influenced individually in real
time.
With the products from the Pan Beam series, you can achieve nearly constant
alignment of the volume within a large listening area and in doing so, direct
the sound flexibly and precisely to the corresponding listener plane(s). This
characteristic of the speakers means, on the one hand, that even when standing
near the speaker, the listener does not need to withstand what is otherwise a
high and unpleasant sound pressure level. On the other hand, at larger
distances, the listener experiences uniform and clearly-audible sound
reproduction with natural sound.
The defining features of Pan Beam products are:
- Perfect design
- Innovative technology
- High-performance DSP control
- Highest level of speech intelligibility and music reproduction
- Flexible and precise alignment (multi-beam technology)
- Efficient digital amplifiers
- Networking
- Flexibility through modularity
- Light weight
- Low power input and low quiescent current
- Integration in EN 60849 systems
2.2. Beam steering technology
The combination of high-performance DSP technology and Pan Beam Setup control
software allows for the configuration of the vertical width and inclination
angle of the beam. It is not necessary to mechanically tilt the speaker, i.e.
the speaker can be mounted vertically, e.g. on a wall.
In this, the length of the sound column determines the maximum bundling in low
frequencies. The longer an array is, the better the control over low
frequencies.
2.3. Multi beam steering technology
From PB 08 and PB 248, the Pan Beam column speakers offer the capability of
multi-beam steering technology. This allows for the generation of more than
one beam from one column. As a result, the beam energy can be ideally
distributed among the surfaces onto which sound is projected, e.g. orchestra
level, first balcony, second balcony in the theater. Where required, each of
the beams generated can be defined in terms of its volume.
2.4. Side lobe optimization
The Pan Beam column speakers offer a DSP function enabling the optimization of
so-called side lobes. In addition to the “max. SPL”, there are also two
additional functions available: “SPL + side lobe” and “min. side lobe”.
Through side lobe optimization, reflections caused by the physical
characteristics of the speaker, e.g. when mounting the unit near glass walls,
can be reduced to a minimum.
Connections
All connections for audio, control data and power supply are located on the
back panel of the speakers. The connections are freely accessible. No tools
are required for connecting the audio signals and power supply.
3.1. Connector panel for Pan Beam PB 04/08/16/24/32/40 – analog/digital
audio (AES/EBU)
| (3) Pan Beam Net connection
RJ45
(2) Pan Beam Net connection
RJ45
(1) Power connection
according to IEC 60320-1 C13 3-pin low-voltage with integrated strain relief
and protective ground conductor Supply voltage: 100–230 V, 50/60 Hz The rental
version is equipped with a PowerCON TRUE1 connector
---|---
3.2. Connector panel for Pan Beam PB 04/08/16/24/32/40 – DANTE
**|
(4) Dante Network secondary port
RJ45 / 1 GBit/s
(3) Dante Network primary port
RJ45 / 1 GBit/s
(2) Pan Beam Net-Link
RJ45
(1) Power connection
** according to IEC 60320-1 C13 3-pin low-voltage with integrated strain
relief and protective ground conductor Supply voltage: 100–230 V, 50/60 Hz
---|---
3.3. Connector panel for Pan Beam PB 224 – analog/digital audio (AES/EBU)
| (3) Pan Beam Net connection
RJ45
(2) Pan Beam Net connection
RJ45
(1) Power connection
PowerCON TRUE1
Supply voltage: 100–230 V, 50/60 Hz
---|---
3.4. Connector panel for Pan Beam PB 224 – DANTE
| (4) Dante Network secondary port
RJ45 / 1 GBit/s
(3) Dante Network primary port
RJ45 / 1 GBit/s
(2) Pan Beam Net-Link
RJ45
(1) Power connection
PowerCon TRUE1, integrated strain relief and protective ground conductor
Supply voltage: 100–230 V, 50/60 Hz
---|---
Commissioning
4.1. Electrical connections
All audio and power supply connections are located on the back panel of the
speakers.
The connections are freely accessible, –> see chapter 3. “Connections”.
For the power supply, the power connection of the speaker is to be made to an
appropriate power source using the included power cord.
The connection for audio signals and control data is established via the RJ45
connector sockets.
DANGER
In order to prevent electrical shock, the modules are only allowed to be
connected to one another when the power is switched off.
NOTICE
To prevent malfunctions, the recommended bending radius of the power and
signal connection cables is to be observed.
4.2. Mounting of speakers, consisting of several modules
The PB 16, PB 24, PB 32 and PB 40 speaker systems consist of two or more
modules. The PB 16 consists of a “bottom” and “top” module. The PB 24, 32 and
40 feature additional intermediate (“middle”) modules. The power and signal
supply is provided via an internal cable assembly with appropriate plug
connectors. The mechanical connection of the individual modules is completed
via connector elements that are inserted into the lateral slots.
Insert the narrow connectors into the lateral slot.| Secure the connectors
using screws (left and right).| Insert the wide connector into the rear slot.
Secure the connector using screws.| Connect the power and signalplug
connectors.| Join the modules and secure them with screws.
NOTICE When joining the modules, the inside cable assembly is to be fed
into the interior of the speakers.
Avoid crushing and bending the cables.
The PB 224, PB 248, PB 272 and PB 296 speaker systems consist of two or more
modules. The PB 248 consists of two PB 224 modules. The PB 272 consists of
three PB 224 and the PB 296 of four PB 224 modules. The power and signal
supply is provided via external cables joined using the appropriate plug
connectors. The mechanical connection is made as with PB 16, 24, 32, 40 via
four connector elements into the two lateral and rear slots. A mounting plate
is pre-fitted on the back panel for wall mounting, in order to fasten
appropriate wall brackets.
4.3. Cascading of the speaker columns with Pan Beam Setup software
The speaker systems PB 16, 24, 32, 40, 248, 272, 296, consisting of several
modules, are to be appropriately cascaded according to the mechanical
connection by means of the Pan Beam Setup software. Please refer to the Pan
Beam Setup manual for the appropriate procedure.
Error description
LED | Display | Meaning |
---|---|---|
0 | off | no power supply |
red glowing/flashing | error | |
illuminated green | ready for operation | |
orange blinking | communication | |
Problem | Cause | Remedy |
--- | --- | --- |
Signal LEDs are not illuminated | Speaker has no power | Check the connection to |
the power supply
Signal LED illuminated / blinking red| Speaker has detected an error| Contact
service department
Signal LED blinking orange| Communication between software and speaker,
communication between media controller and speaker| None, as this is normal
behavior
Connected Pan Beam does
not appear in the software| Pan Beam not connected to Pan Beam Net or DANTE|
Check connection, verify IP address/subnet in DANTE controller
No audio playback| No audio signal connected| Connect audio signal via audio
input on the interface, crosspoint not set in DANTE Controller routing matrix
No audio playback despite connection| Wrong audio input chosen| Check to
ensure that the
audio connection is properly connected
No audio playback despite proper connection| No audio signal, cable defective|
Check audio signal, examine cable at the source
DANTE
Distorted audio playback| Incorrect sample rate configured in the DANTE
controller| Configure proper sample rate
No connection via USB port| USB cable not inserted properly
USB cable defective
USB cable inserted in USB port after Pan Beam Setup program launch| Check to
ensure that the cable is properly connected
Replace USB cable
Relaunch Pan Beam Setup program.
Media controller does not work| Pin configuration incorrect Baud rate
incorrect
Faulty instruction set| Check pin configuration Configure proper baud rate
Check instruction set
If the error is not specifi ed in the above table or cannot be remedied using
the measures mentioned, please consult the technical support of Pan Acoustics
GmbH.
Please retain the original packaging of the devices in order to ensure secure
return shipping in the event of a claim. The risk of shipping damage is
minimized by the original packaging.
5.1. Service and repair
Service and repair work are only allowed to be carried out by persons and
partners instructed by Pan Acoustics.
No service or repair work is allowed to be made on the device above and beyond
the statements made in the maintenance manual.
Contact data:
–> see chapter 5.5. “Contact address”
5.2. Maintenance measures
The following measures are to be carried out at regular intervals:
Cleaning
The enclosure should be regularly dusted off with a damp cloth and thereby
examined for any damage.
Visual and functional inspection
The installed device should be regularly subjected to a visual inspection.
The following items are to be carried out:
- Check the connections on the Pan Beam Net interface and on the speaker to ensure a proper fit.
- Check the bracket for wall and ceiling mount for a firm fit.
- Check the enclosure for damage.
- Check network connection cable for damage.
EC conformity (CE mark)
** The declaration of conformity for the relevant product from the Pan Beam
series can be requested from Pan Acoustics.
5.4. WEEE declaration (disposal)
The waste bin symbol points out that electrical and electronic components are
not allowed to be disposed of in household waste. This symbol is found on our
products.
If the product is to be disposed of, please consult with your dealer or
distributor.
5.5. Contact address
** Pan Acoustics GmbH
Lindener Straße 15
38300 Wolfenbüttel
Germany
Tel: +49 (0) 5331 900 95 70
Fax: +49 (0) 5331 900 95 79
Email: support@pan-acoustics.de
Appendix
6.1. Pan Beam Net – RJ45 pin configuration
Pin | Description |
---|---|
1 | Input A + |
2 | Input A – |
3 | Relay contact + |
4 | Input B + (AES/EBU) |
5 | Input B – (AES/EBU) |
6 | Relay contact – |
7 | RS485 + |
8 | RS485 – |
Enclosure | PG (earth/ground) shielding |
6.2. Alarm contact (alarm loop)
Each Pan Beam speaker has an alarm contact. Via this alarm contact, the
speaker can display a detected error. For this purpose, a switch relay is
installed in the speaker, which is connected in normal operating status. If
the speaker is not in operation, there is no power supply, or if an internal
error is signaled via the DSP, the relay is opened.
In the Pan Beam Net, all devices are interconnected by means of daisy chain
cabling. In order to close the loop for the alarm contact, create a jumper
between pin 3 and pin 6 (–> see chapter 6.1. “Pan Beam Net – RJ45 pin
configuration”) on the device located at the end of the cabling. Via the Pan
Con and Pan Splitter interfaces, the alarm loop can now be evaluated, e.g. via
a GPI on the media controller. To do so, the 3-pin connector on the Pan Beam
Net interface is to be connected with the device accordingly.
6.3. Control via media controller
6.3.1. Pan Beam Net
Via the Pan Splitter 4/4 and Pan Splitter 2/6 interfaces, previous confi
gurations (so-called presets) saved in the speaker can be activated using a
media controller. To do so, connect the media controller to the specifi ed
interfaces via the RS485 interface.
–> See chapter 7. “Interfaces”.
The following control commands must be transmitted completely. It is important
to take the below timing into account. There is no feedback message. All Pan
Beam speakers in the audio network execute the command.
Timing
A wait interval of at least 3 s must be adhered to between the individual
commands.
NOTICE
Mixed operation on the RS485 bus with other devices of third-party
manufacturers is not allowed due to the different protocols!
On connected Pan Beam speakers, this may lead to a malfunction and/or failure
of a speaker.
Reactivation is only possible via technical support.
Parallel operation of the media controller and the Pan Beam Setup program is
not possible and should be avoided.
Control commands
Calling up presets | String (HEX) |
---|---|
Preset 1 | 0x02 0x46 0x46 0x46 0x45 0x52 0x1C 0x30 0x31 0x1C 0x30 0x32 0x30 |
0x32 0x0D
Preset 2| 0x02 0x46 0x46 0x46 0x45 0x52 0x1C 0x30 0x32 0x1C 0x30 0x32 0x30
0x33 0x0D
Preset 3| 0x02 0x46 0x46 0x46 0x45 0x52 0x1C 0x30 0x33 0x1C 0x30 0x32 0x30
0x34 0x0D
Preset 4| 0x02 0x46 0x46 0x46 0x45 0x52 0x1C 0x30 0x34 0x1C 0x30 0x32 0x30
0x35 0x0D
Preset 5| 0x02 0x46 0x46 0x46 0x45 0x52 0x1C 0x30 0x35 0x1C 0x30 0x32 0x30
0x36 0x0D
NOTICE
The prefix 0x in the string (HEX) must be adapted or can be omitted depending
upon the media controller used. For this purpose, please refer to relevant
information on the instruction manual of the media controller used.
6.3.2. Crestron
The relevant module is ready for operation with a media controller by the
manufacturer Crestron. The module can be obtained through the Crestron website
or from Pan Acoustics.
6.3.3. Pan Beam Net interface confi guration, Crestron
baud rate | 38400 ± 3% |
---|---|
data bits | 8 |
parity | none |
stop bits | 2 |
flow control | none |
6.4. DANTE
6.4.1. Setup
The speakers in the Pan Beam series are to be set up through the Pan Beam
Setup software. The Audinate software DANTE Controller is to be installed for
software access to DANTE network. After successful installation, the DANTE
interface appears in the bottom line of the Pan Beam Setup software.
The DANTE controller can be launched via the “Interface” menu item in the Pan
Beam Setup program.
The DANTE Controller software in its latest version must be properly
installed. Link for download: http://www.audinate.com
6.4.2. Routing
A Pan Beam speaker appears in the DANTE network under the “DANTE Receivers”
tab. The speaker features two inputs, Input A and Input B.
For audio routing, the relevant connection is to be set between the desired
DANTE transmitter and the Pan Beam speaker.
NOTICE
Via the Pan Beam Setup software, the relevant audio source is also to be
activated (Input A and/or Input B).
6.4.3. Device Config
The DANTE interface allows to adjust various settings of the Pan Beam speakers
via the “Device Confi g” tab.
Rename device:
Assign name for the speaker
Sample rates:
44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz, 176.4 kHz, 192 kHz
Encoding:
Pan Beam speakers support PCM24 and PCM32 encoding
Device latency and clocking
See Audinate Dante information at http://www.audinate.com
6.4.4. Network confi guration
The DANTE interface of the Pan Beam speakers supports the “switched” and
“redundant” modes in the DANTE network.
Switched:
If the DANTE interface is set to “switched”, an additional DANTE device can be
connected on the secondary port, e.g. a stage box, and operated in the DANTE
network.
Redundant:
If the DANTE interface is set to “redundant”, the Pan Beam speaker can be
connected with a second network cable to the redundantly-confi gured DANTE
network.
6.4.5. Status
Via the “Status” tab, information can be called up on the device, fi rmware
and software version, clock status and network interface.
6.4.6. Cascading (4) Pan Beam Net-Link
Via the Pan Beam Net-Link RJ45 port, additional Pan Beam speakers can be
connected with the AES/EBU interface in a daisy chain procedure.
Pay attention to the proper sequence (Input/Output).
Marking (1) to (4) See chapter 3.2. “Connector panel for Pan Beam PB
04/08/16/24/32/40 – DANTE” or chapter 3.4. “Connector panel for Pan Beam PB
224 – DANTE”
6.4.7. Media controller
Via the DANTE audio network, it is possible to activate the saved
configurations (presets) via UDP commands.
The following control commands must be transmitted completely. It is important
to take the below timing into account. There is no feedback message. All Pan
Beam speakers in the audio network execute the command.
Timing
A wait interval of at least 3 s must be adhered to between the individual
commands.
Network address and port
Address: 224.0.1.4
Port: 4712
Calling up presets | String (HEX) |
---|---|
Preset 1 | 50 41 4e 41 43 4f 55 53 54 49 43 53 02 46 46 46 45 52 1c 30 31 1c |
30 32 30 32 0d
Preset 2| 50 41 4e 41 43 4f 55 53 54 49 43 53 02 46 46 46 45 52 1c 30 32 1c 30
32 30 33 0d
Preset 3| 50 41 4e 41 43 4f 55 53 54 49 43 53 02 46 46 46 45 52 1c 30 33 1c 30
32 30 34 0d
Preset 4| 50 41 4e 41 43 4f 55 53 54 49 43 53 02 46 46 46 45 52 1c 30 34 1c 30
32 30 35 0d
Preset 5| 50 41 4e 41 43 4f 55 53 54 49 43 53 02 46 46 46 45 52 1c 30 35 1c 30
32 30 36 0d
6.4.8. Alarm contact (alarm loop)
Each Pan Beam speaker has an alarm contact. Via this alarm contact, the
speaker can report a detected error. For this purpose, a switch relay is
installed in the speaker, which is closed in normal operating status. If the
speaker is not in operation, there is no power supply, or if an internal error
is signalled via the DSP, the relay is opened.
Pan Beam speakers connected to a DANTE network also have this function. This
function can be used via the Pan Beam Net-Link interface.
This is achieved by connecting the speaker to an appropriate interface, e.g.
Pan Con, via the Pan Beam Net-Link interface by means of a network cable. Via
the alarm contact on the Pan Con interface, the alarm contact status can be
monitored by means of a GPI on the media controller.
Interfaces
Various interfaces are available for the operation and setup of a Pan Beam
network.
7.1. Pan Con
-
Audio A
Audio input A for analog audio signals -
Audio B
Audio input B for analog and digital audio signals -
LED TRX
Illuminated orange during data transfer -
USB (B) connector
for link to PC -
LED PWR
Illuminated green when voltage detected via USB port -
Alarm
–> see chapter 6.2. “Alarm contact” -
Pan Beam
RJ45 connector for Pan Beam speakers
7.2. Pan Splitter 4/4
-
Audio A
Audio input A for analog audio signals -
Pan Beam
RJ45 connection for Pan Beam speakers -
LED PWR
Illuminated green when voltage detected via USB port -
Alarm
–> see chapter 6.2. “Alarm contact” -
LED TRX
Illuminated orange during data transfer -
USB (B) connector
for link to PC -
LED EXT
Illuminated when externally controlled via (8) -
RS485 Input
2-pin connection for media controller
–> See chapter 6.3. “Media Controller”
7.3. Pan Splitter 2/6
-
Audio A
Audio input A for analog audio signals -
Pan Beam
RJ45 connection for Pan Beam speakers -
LED PWR
Illuminated green when voltage detected via USB port -
Alarm
–> see chapter 6.2. “Alarm contact” -
LED TRX
Illuminated orange during data transfer -
USB (B) connector
for link to PC -
LED EXT
Illuminated when externally controlled via (8) -
RS485 Input
2-pin connection for media controller
–> See chapter 6.3. “Media Controller”
NOTICE
For media control operation, Pan Splitter 2/6 and Pan Splitter 4/4 are to be
powered via the USB port.
NOTICE
Pan Splitter 2/6 and Pan Splitter 4/4 are not AES/EBU-capable. Digital audio
signals (AES/EBU) can only be fed in into a Pan Beam network via the Pan Con
interface. Parallel operation of analog and digital signals in one network is
to be avoided in order to prevent defects in the speakers.
Pan Beam Net
8.1. Configuration
Pan Beam Net is a line bus system with which the Pan Beam speakers are
connected to one another in so-called daisy-chain cabling. For the linking of
speakers, a category CAT 5e or higher twisted-pair cable (network cable)
should be used. The audio signals (analog or digital), the control data and
the alarm loop are transferred via this cable.
The Pan Beam Net is confi gured to enable continued signal transfer in case a
speaker in the line should fail. In case of failure, the alarm loop is
interrupted accordingly and the error status in the system can be evaluated on
an appropriate interface. For this purpose, the Pan Net jumper plug is to be
used according to the cabling examples.
Pan Beam Net enables up to 256 Pan Beam speakers per line to be operated over
a total length per line of up to 300m.
Cabling examples for the various interfaces are displayed below.
8.2. Pan Con cabling example
8.3. Pan Con cabling example (alarm contact)
NOTICE
The Pan Net jumper plug is to be plugged into the open RJ45 slots on the Pan
Beam speaker. This completes the return path for the alarm loop.
8.4. Pan Splitter 2/6 cabling example
8.5. Pan Splitter 2/6 cabling example (alarm contact)
NOTICE
The Pan Net jumper plug is to be plugged into the open RJ45 slots on the Pan
Beam speaker. This completes the return path for the alarm loop.
8.6. Pan Splitter 4/4 cabling example 8.7. Pan Splitter 4/4 cabling
example (alarm contact)
NOTICE
The Pan Net jumper plug is to be plugged into the open RJ45 slots on the Pan
Beam speaker. This completes the return path for the alarm loop.
Scope of delivery and accessories
In its standard configuration, the Pan Beam series consists of the modules PB
04 and PB 08 as well as PB 224. As already mentioned in Chapter 4.2.
“Installation of speakers, consisting of several modules” the modules PB 08
and PB 224 can be connected to longer arrays. Depending upon the length of the
array, the delivery scope of the speakers consists of the following:
9.1. Delivery scope of speakers
9.1.1. PB 04
Description | Quantity |
---|---|
PB 04 module | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.2. PB 04 – AES/EBU
Description | Quantity |
---|---|
PB 04 – AES/EBU module | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.3. PB 04 – D
Description | Quantity |
---|---|
PB 04 – D module | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.4. PB 08
Description | Quantity |
---|---|
PB 08 module | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.5. PB 08 – AES/EBU
Description | Quantity |
---|---|
PB 08 – AES/EBU module | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.6. PB 08 – D
Description | Quantity |
---|---|
PB 08 – D module | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.7. PB 16
Description | Quantity |
---|---|
PB 08 module (bottom) | 1 |
PB 08 module (top) | 1 |
Connection set PB xx | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.8. PB 16 – AES/EBU
Description | Quantity |
---|---|
PB 08 – AES/EBU module (bottom) | 1 |
PB 08 – AES/EBU module (top) | 1 |
Connection set PB xx | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.9. PB 16 – D
Description | Quantity |
---|---|
PB 08 – D module (bottom) | 1 |
PB 08 – AES/EBU module (top) | 1 |
Connection set PB xx | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.10. PB 16 (one enclosure)
Description | Quantity |
---|---|
PB 16 module | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.11. PB 16 – AES/EBU (one enclosure)
Description | Quantity |
---|---|
PB 16 – AES/EBU | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.12. PB 16 – D (one enclosure)
Description | Quantity |
---|---|
PB 16 – D | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.13. PB 24
Description | Quantity |
---|---|
PB 08 module (bottom) | 1 |
PB 08 module (middle) | 1 |
PB 08 module (top) | 1 |
Connection set PB xx | 2 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.14. PB 24 – AES/EBU
Description | Quantity |
---|---|
PB 08 – AES/EBU module (bottom) | 1 |
PB 08 – AES/EBU module (middle) | 1 |
PB 08 – AES/EBU module (top) | 1 |
Connection set PB xx | 2 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.15. PB 24 – D
Description | Quantity |
---|---|
PB 08 – D module (bottom) | 1 |
PB 08 – AES/EBU module (middle) | 1 |
PB 08 – AES/EBU module (top) | 1 |
Connection set PB xx | 2 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.16. PB 24 (one enclosure)
Description | Quantity |
---|---|
PB 24 module | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.17. PB 24 – AES/EBU (one enclosure)
Description | Quantity |
---|---|
PB 24 – AES/EBU module | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.18. PB 24 – D (one enclosure)
Description | Quantity |
---|---|
PB 24 – D module | 1 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.19. PB 32
Description | Quantity |
---|---|
PB 08 module (bottom) | 1 |
PB 08 module (middle) | 2 |
PB 08 module (top) | 1 |
Connection set PB xx | 3 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.20. PB 32 – AES/EBU
Description | Quantity |
---|---|
PB 08 – AES/EBU module (bottom) | 1 |
PB 08 – AES/EBU module (middle) | 2 |
PB 08 – AES/EBU module (top) | 1 |
Connection set PB xx | 3 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.21. PB 32 – D
Description | Quantity |
---|---|
PB 08 – D module (bottom) | 1 |
PB 08 – AES/EBU module (middle) | 2 |
PB 08 – AES/EBU module (top) | 1 |
Connection set PB xx | 3 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.22. PB 40
Description | Quantity |
---|---|
PB 08 module (bottom) | 1 |
PB 08 module (middle) | 3 |
PB 08 module (top) | 1 |
Connection set PB xx | 4 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.23. PB 40 – AES/EBU
Description | Quantity |
---|---|
PB 08 – AES/EBU module (bottom) | 1 |
PB 08 – AES/EBU module (middle) | 3 |
PB 08 – AES/EBU module (top) | 1 |
Connection set PB xx | 4 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.24. PB 40 – D
Description | Quantity |
---|---|
PB 08 – D module (bottom) | 1 |
PB 08 – AES/EBU module (middle) | 3 |
PB 08 – AES/EBU module (top) | 1 |
Connection set PB xx | 4 |
IEC-60320 C13 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.25. PB 224
Description | Quantity |
---|---|
PB 224 module | 1 |
Pre-mounted connection plate for fastening a bracket | 1 |
PowerCON TRUE1 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.26. PB 224 – AES/EBU
Description | Quantity |
---|---|
PB 224 – AES/EBU module | 1 |
Pre-mounted connection plate for fastening a bracket | 1 |
PowerCON TRUE1 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.27. PB 224 – D
Description | Quantity |
---|---|
PB 224 – D module | 1 |
Pre-mounted connection plate for fastening a bracket | 1 |
PowerCON TRUE1 power cord | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.28. PB 248
Description | Quantity |
---|---|
PB 224 module | 2 |
Pre-mounted connection plate for fastening a bracket | 2 |
Connection set PB xxx | 1 |
PowerCON TRUE1 power cord | 1 |
Connection cable set PB xxx PB xxx | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.29. PB 248 – AES/EBU
Description | Quantity |
---|---|
PB 224 – AES/EBU module | 2 |
Pre-mounted connection plate for fastening a bracket | 2 |
Connection set PB xxx | 1 |
PowerCON TRUE1 power cord | 1 |
Connection cable set PB xxx | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.30. PB 248 – D
Description | Quantity |
---|---|
PB 224 – D module | 1 |
PB 224 – AES/EBU module | 1 |
Pre-mounted connection plate for fastening a bracket | 2 |
Connection set PB xxx | 1 |
PowerCON TRUE1 power cord | 1 |
Connection cable set PB xxx | 1 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.31. PB 272
Description | Quantity |
---|---|
PB 224 module | 3 |
Pre-mounted connection plate for fastening a bracket | 3 |
Connection set PB xxx | 2 |
PowerCON TRUE1 power cord | 1 |
Connection cable set PB xxx | 2 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.32. PB 272 – AES/EBU
Description | Quantity |
---|---|
PB 224 – AES/EBU module | 3 |
Pre-mounted connection plate for fastening a bracket | 3 |
Connection set PB xxx | 2 |
PowerCON TRUE1 power cord | 1 |
Connection cable set PB xxx | 2 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.33. PB 272 – D
Description | Quantity |
---|---|
PB 224 – D module | 1 |
PB 224 – AES/EBU module | 2 |
Pre-mounted connection plate for fastening a bracket | 3 |
Connection set PB xxx | 2 |
PowerCON TRUE1 power cord | 1 |
Connection cable set PB xxx | 2 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.34. PB 296
Description | Quantity |
---|---|
PB 224 module | 4 |
Pre-mounted connection plate for fastening a bracket | 4 |
Connection set PB xxx | 3 |
PowerCON TRUE1 power cord | 1 |
Connection cable set PB xxx | 3 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.35. PB 296 – AES/EBU
Description | Quantity |
---|---|
PB 224 – AES/EBU module | 4 |
Pre-mounted connection plate for fastening a bracket | 4 |
Connection set PB xxx | 3 |
PowerCON TRUE1 power cord | 1 |
Connection cable set PB xxx | 3 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.1.36. PB 296 – D
Description | Quantity |
---|---|
PB 224 – D module | 1 |
PB 224 – AES/EBU module | 3 |
Pre-mounted connection plate for fastening a bracket | 4 |
Connection set PB xxx | 3 |
PowerCON TRUE1 power cord | 1 |
Connection cable set PB xxx | 3 |
Closure cap (rubber) for RJ45 interface | 1 |
Quick start instructions | 1 |
9.2. Pan Net interfaces
9.2.1. Pan Con
9.3. Brackets
9.2.2. Pan Splitter 2/6
9.2.3. Pan Splitter 4/4
Wall bracket, fixed, PB xx Article no.: 801839
Wall bracket, can be moved horizontally, PB xx (TWM II) Article no.: 801840
Wall bracket, horizont. and vertic. adjustable by +/- 5°, PB xx (TWM
III)Article no.: 801841
Tripod attachment, PB xx Article no.: 801843
Connection set, PB xx Article no.: 801924
Wall bracket, swiveling/tiltable, PB 224 Article no.: 801314 Fastening plate,
PB 2xx
Article no.: 800388
Tripod attachment, PB 224
Article no.: 800392
Connection set, PB 2xx
Article no.: 800393
Universal wall mount, swiveling/tiltable
Article no.: 801365 Wall bracket, swiveling/tiltable
Article no.: 801449
Base stand for speakers, “RingLock”
Article no.: 801488
Base stand for speakers
Article no.: 801581
Ceiling bracket (fi xed), PB xx
Article no.: 801451 Ceiling bracket (expandable), PB xx
Article no.: 801285 The accessories with the article numbers: 801365, 01449,
801451, 801581 are also available in the color RAL 9010 (white).
Performance Specifications
Please refer to the corresponding data sheets of the speakers for performance
specifications.
These are available at www.pan-acoustics.de.
TECHNOLOGY
Audio, data and power over only 2-wire-system, e.g. I-Y(ST)Y of existing
100V-system. Pan Powerline is an option for several products of the Pan Beam
series.
PASSIVE COLUMN SPEAKER
Shapely. Versatile. Functional..
Solid. Different performance levels.
Applications: Live and fi xed installations.
PAN ACOUSTICS COMBINES
EXPERTISE AND KNOW-HOW
We create products with a unique sound performance.
We create solutions for acoustics challenges.
We create products with weatherproof option (IP 54/ IP 65), seawater proof and
temperature resistant (-30°C – 80°C).
All products are designed, developed and manufactured with high-quality
materials according to the strict criteria by
Pan Acoustics from Germany.
QUALITY – MADE IN GERMANY
CONTACT:
Pan Acoustics GmbH | Lindener Str. 15
D-38300 Wolfenbüttel | Germany
Tel: +49 (0) 5331 900 95 70
Fax: +49 (0) 5331 900 95 79
Mail: contact@pan-acoustics.de
www.pan-acoustics.de
PAN ACOUSTICS PRODUCTS:
Documents / Resources
| PAN
ACOUSTICS PB 04 Pan Beam series with Beam
Steering
[pdf] Instruction Manual
PB 04 Pan Beam series with Beam Steering, PB 04, Pan Beam series with Beam
Steering, Beam Steering
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>