User Manual
Technotherm VPS, VPS H, VPS DSM, VPS plus, VPS RF l Partial Thermal-Storage Heaters
Types:
Please read attentively and keep in a safe place!
Subject to alterations!
Id_no. 911 360 870
Issue 08/18
Feel good through warmth from electricity – www.technotherm.de
1. General information about our surface storage heaters
With our variety of electric surface storage heaters, you can find the right solution for your needs in any spatial situation. The TECHNOTHERM partial thermal-storage heaters are available as additional or transitional heating for all rooms in the living area, with the exception of the special cases stated in the safety instructions. They are designed for continuous operation. Prior to dispatch, all our products undergo an extensive function, safety and quality test. We guarantee a constructive design complying with all currently applicable international, European and German safety standards and rules. You can see this in the labelling of our products with the well-known certification marks: “TÜV-GS”, “SLG-GS”, “Keymark” and “CE”. Our heaters are evaluated in accordance with the internationally applicable lEC-regulations. The manufacture of our heaters is constantly supervised by a state-accredited test centre.
This heater can be used by children aged from 8 years and above and by
physically, sensory or mentally restricted persons if they are supervised or
given instructions on safe use and understand the hazards involved as it does
not require any experience or knowledge. This device is not a toy for children
to play with! Cleaning and user maintenance shall not be carried out by
children without supervision. The use of heat radiators is to be given a
particular duty of care by supervisors. Children under the age of 3 are to be
kept away unless they are continually supervised. Children between the age of
3 and 8 are only allowed to switch the heater on or off if they are supervised
or given instructions on safe use and understand the hazards involved,
provided that it has been placed or installed in its intended normal operating
position. Children between the age of 3 and 8 shall not plug in, regulate and
clean the heater or perform user maintenance.
Caution: Some parts of the product can become very hot and cause burns.
Pay particular attention when children and vulnerable people are present.
Warning! this device has to be grounded
This device may only be operated using alternating current and the operating
voltage indicated on the power rating plate
- Nominal Voltage: 230V AC, 50 Hz
- Protection Class: I
- Degree of Protection: IP 24
- Room Thermostat: 7°C till 30°C
2. User Manuel VPS RF Model
2.1.1 Setting the Room Thermostat
Press the receiver button for more than 3 seconds, until the indicator light
begins to flash. Subsequently press the transmitter key in the configuration
mode. (see User Manual Receiver) As soon as the indicator light stops flashing
the two products are assigned.
2.1.2 Setting the sender
Press the receiver button for at least 3 seconds until the indicator light
starts flashing.
Two modes of operation are possible.
- Slow flashing: On\Off switch
- Fast flashing: instigator
To switch the mode again, press the key briefly. Take the transmitter into the Configuration mode (see user manual transmitter). Check that the indicator light is no longer flashing.
Application Example
The use of a room thermostat in combination with a opening detector is ideal,
because the opening detector will detect if a window is open and will
automatically switch to frost protection. By pressing the receiver button for
approximately 10 seconds, you can change the relay´s setting. You know the
setting is changed as soon as the signal light stops flashing.
2.1.3 Deleting Allocation s
To delete the setting simply press the receiver key for approximately 30
seconds until you see the receiver light flash briefly. All transmitters are
now deleted.
2.1.4 Receiver RF- Technical Specifications
- Power Supply 230 V, 50 Hz +/-10%
- Protection Class II
- Expenditure : 0,5 VA
- Switching capacity max.: 16 A 230 Veff Cos j =1 or max. 300 W with lighting control
- Radio Frequency 868 MHz (NormEN 300 220),
- Radio Range up to 300 m in an open field, indoors up to ca. 30m, depending on the construction of the building and the electromagnetic interference
- Maximal Number of receivers: 8
- Mode of operation: type 1.C (Micro-disconnection)
- Operating Temperature: -5°C to +50°C
- Storage Temperature: -10 °C +70°C
- Dimensions: 120 x 54 x 25 mm
- Degree of Protection : IP 44 – IK 04
- To be installed in average polluted Areas4. Installation DSM Thermoastat / DAS Schnittstelle.
WARNING
Do not install this device in areas that present an explosion hazard like a
garage. Remove all protective coverage before turning on the device. When
using the device for the first time you might detect a strong odor. This is no
reason for concern; it is caused by residues of production and will disappear
shortly.
The rising heat may cause stains on the ceiling, however this phenomena can be caused by any other heating device as well. Only a qualified electrician may open or remove the device from the power supply.
3. User Manuel for the VPS DSM
Please see additional manual at www.lucht-lhz.de/lhz-app- gb.html and download the manual
4. Maintenance
Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent.
5. Details for operation of Types VPS plus /VPS H plus/VPS TDI
Configuration
When in Off mode, press and hold down the On/Off button for 10 seconds to access the first configuration menu.
Menu 1: ECO set-point adjustment
By default, Economy setting = Comfort setting – 3.5°C.
This reduction can be set between 0 to -10°C, in steps of 0.5°C.
To adjust
the reduction, press on the + or – buttons then press OK to confirm and go to
the next setting.
To allow the user to modify the set-point, press on the + button in Economy mode until “—-” is displayed on the screen.
Menu 2: Correction of the measured temperature
If there is a difference between the temperature noted (thermometer) and the temperature measured and displayed by the unit, menu 2 acts on the measurement of the probe so as to compensate for this difference (from -5°C to +5°C in steps of 0.1°C).
To modify, press on the + or – buttons then press OK to confirm and go to the next setting.
Menu 3: Backlight time out setting
The time out can be adjusted between 0 and 225 seconds, in steps of 15 seconds (set on 90 seconds by default).
To modify, press on the + or – buttons then press OK to confirm and go to the next setting.
Menu 4: AUTO mode temperature display option
0 = Continuous display of room temperature.
1 = Continuous display of set-point temperature.
To modify, press on the + or – buttons then press OK to confirm and go to the next setting.
Menu 5: Product number
This menu allows you to view the product
To exit the configuration mode, press OK.
Time Setting
In Off mode, press the mode button.
The days flash.
Press + or – to set the day, then press OK to confirm and go on to set the
hour and then the minutes.
Press the mode button once to access the programming, and press the On/Off button once to exit the setting mode.
Programming
When starting up, the “Comfort mode from 8am to 10pm” program is applied to
all the days of the week.
To change the programming, press the PROG button in Off or AUTO mode.
The 1st time slot flashes on and off.
Quick programming:
To apply the same program to the following day, press and hold the OK button
for approximately 3 seconds until the program of the following day is
displayed. To exit the programming mode, press on the On/Off button.
Use
The Mode button allows you to select the different operating modes Comfort,
Economy, Frost protection, programming AUTO mode.
Pressing the i button gives you the temperature of the room or the set-
point temperature, according to your configuration settings in menu 5.
If the ON icon is displayed, this means that the device is in heating demand
mode.
Continuous Comfort
Pressing and holding the + or – buttons lets you change the current set-point
(+5 to +30°C) in steps of 0.5°C.
Continuous Economy mode
The Economy set-point is indexed according to the Comfort set-point. The
reduction can be modified in the configuration settings for menu 1.
Modifying the Economy set-point
The set-point can be modified if it was authorized in the configuration
settings in menu 1 (“—-”).
Pressing and holding the + or – buttons lets you change the current set-point (+5 to +30°C) in steps of 0.5°C.
Continuous Frost Protection
Pressing and holding the + or – buttons lets you change the current set-point
(+5 to +15°C) in steps of 0.5°C.
AUTOMATIC mode
In this mode the device follows the programming set.
To modify the programming, press the PROG button once.
Timer mode
- To set a set-point temperature for a certain period of time, press on the button once.
- To set the temperature you want (+5°C to +30°C), use the + and – buttons, then press OK to confirm and go on to set the duration.
- To set the duration you want (30 min to 72 hours, in steps of 30 min), use the + and – buttons (e.g. 1 hr 30 min), then press OK.
- To cancel the timer mode, press on the OK button.
Absence mode
-
You can set your device to Frost protection mode for a period between 1 and 365 days,
by pressing on the button. -
To set the number of days of absence, press on the + or – buttons, then confirm by pressing OK.
-
To cancel this mode, press on the OK button again.
Locking the keypad
-
If you press and hold the central buttons simultaneously during 5 seconds, it enables you to lock the keypad. A key symbol appears briefly on the display.
-
To unlock the keypad, press simultaneously on the central buttons.
-
Once the keypad is locked, the key symbol appears briefly if you press on a button.
Menu 5: Open Window detection
The detection of an open window occurs when the room temperature falls
rapidly.
In this case, the display shows a flashing pictogram, as well as the frost
protection set-point temperature.
0 = Open window detection is deactivated
1 = Open window detection is activated
- To modify, press on the + or – buttons, then press OK to confirm and to go to the next setting.
- Please note: an open window cannot be detected in OFF-Mode.
- This feature can be temporarily interrupted by pressing on .
Menu 6: Adaptive start control
This feature enables to reach the set-point temperature at a set time.
When this feature is activated, the display shows a flashing .
0 = Adaptive start control deactivated
1 = Adaptive start control activated
To modify, press on the + or – buttons, then press OK to confirm and to go to the next setting.
Adjusting the time-temperature-slope (when adaptive start control is activated)
From 1°C to 6°C, in steps of 0.5°C.
If the set-point temperature is reached too early, then a lower value should
be set.
If the set-point temperature is reached too late, then a higher value should
be set.
Menu 7: Productnumber
This menu allows you to view the product number.
To exit the configuration mode, press OK.
Technical characteristics
- Power supplied by the power card
- Dimensions in mm (without mounting lugs): H = 71.7, W = 53, D= 14.4
- Screw-mounted
- Install in an environment with normal pollution levels
- Storage temperature: -10°C to +70°C
- Operating temperature: 0°C to +40°C
6. Assembly instruction
This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this manual to any other succeeding owner of the device. The device comes with a power plug that has to be plugged into an outlet.
The device is designed to be connected to 230V (nominal) alternating current (AC).
7. Wall Installation
When installing the device, the safety distance must be strictly adhered to, so that flammable materials can not ignite. Install the device to a wall which is heat resistant up to 90 ° C.
Due to possible fire hazard the safety distances are observed during assembly:
- Side walls of the heater to any masonry: 5 cm
- Side walls of the heater to combustible materials: 10 cm
- Distance radiator to the floor: 25 cm
- Arranged spaced upper radiator limit to about components or covers (. Eg window):
flammable 15 cm
nonflammable 10 cm
To prevent inflammable materials from catching fire be sure to keep the prescribed safety distance when installing the device. Mount the device to a wall that is fireproof up to 90 °C.
The safety distance to the floor should be 25 cm, and at least 10 cm to all other devices. Furthermore there has to be safety distance of approximately 50 cm between the ventilation grille, windowsills, roof slopes and ceilings.
If you want to install the device in your bathroom, be sure to keep it out of reach for people taking a shower or a bath.
When mounting the device to the wall, be sure to keep to the dimensions as indicated in the illustration on page 11. Drill two or three (if available) 7 mm holes and attach the corresponding plug. Then screw the 4 x 25 mm screws into the holes, leaving a distance of 1-2mm between the head of the screw and the wall.
Hang the device in the two or three fittings and tighten it down. See also the additional mounting information at the following pages!
8. Wall Mounting
9. Installation of Electricity
The device was developed for an electrical voltage of 230 V(nominal) and an alternating current of (AC) 50 Hz. The electrical installation may only be performed according to the user manual and only by a qualified Electrician. The device was designed to be used with termination and the connection cable has to be plugged into an appropriate socket at all times. (Notice Permanent cables may not be used) The distance between the receptacle and the device hast to be at least 10cm. The connection line may not touch the device at any time.
10. Regulation
From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of the Ecodesign requirements 2015/1188.
The installation and commissioning of the devices is only permitted in conjunction with external room temperature controllers that fulfill the following functions:
- Electronic room temperature control and has at least one of the following properties:
- Room temperature control, with presence detection
- Room temperature control, with open window detection
- With distance control option
- With adaptive start control
The following room temperature controller systems
- RF Receiver together with the TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco-Interface (Art.Nr.750 000 640) or
- DSM-Thermostat with the DSM-Interface (Art.No.:911 950 101)
- TDI- Thermostat / plus-Thermostat
From Technotherm meet the following requirements and therefore the ErP Directive:
- Electronic room temperature control plus week timer (RF/DSM/TDI)
- Room temperature control, with open window detection (DSM/plus/TDI)
- With distance control option (DSM/RF)
- With adaptive start control (DSM/plus/TDI)
Use of the VPS / VP Standard range (without external/internal thermostat control) is only permitted on feet.
Installation of the receiver and the interfaces see separate instructions. For customer service – see last page.
Failure to comply with these requirements will result in the loss of the CE mark.
11. Additional wall mounting information
- Drill three holes of 7mm and fix the wall bracket. Screw in the three 4 x 25 mm screws into the wall
- Click the heater first at the top into the wall bracket and then at the bottom. The heater will be fixed “automatically”.
11. Information requirements for electrical local space heaters
TECHNOTHERM After-sales service:
Ph. +49 (0) 911 937 83 210
Technical alternations, errors, omissions and errata reserved. Dimensionsare stated without warranty! Updated: august 18
Technotherm is a label from Lucht LHZ GmbH & Co. KG
Reinhard Schmidt-Str. 1 | 09217 Burgstädt, Germany
Phone: +49 3724 66869 0
Telefax: +49 3724 66869 20
info@technotherm.de | www.technotherm.de
Read More About This Manual & Download PDF:
Technotherm VPS, VPS H, VPS DSM, VPS plus, VPS RF l Partial Thermal-Storage
Heaters User Manual – Download [optimized]
Technotherm VPS, VPS H, VPS DSM, VPS plus, VPS RF l Partial Thermal-Storage
Heaters User Manual – Download
Questions about your Manual? Post in the comments!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>